|  Preferred typ |
|
Ordering details |
|
Product type description | BNS 260 STW-AS-R |
Article number | 101186157 |
EAN Code | 4030661333670 |
eCl@ss | 27-27-24-02 |
|
Approval |
|
Approval | AS-i
USA/CAN
TÜV |
|
Classification |
|
Standards | EN ISO 13849-1, IEC 61508 |
PL | up e |
Control category | bis 4 |
PFH | 6.21 x 10-9 / h |
- notice | up to max. 500.000 switching cycles/year |
SIL | up 3 |
Mission time | 20 Years |
|
Global Properties |
|
Permanent light | BNS 260 AS |
Standards | EN 50295, IEC 60947-5-3, EN ISO 13849-1, IEC 61508 |
Compliance with the Directives (Y/N)  | Yes |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic |
- Material of the cable mantle | LSYY |
Weight | 100 |
Coding available (Y/N) | Yes |
Response time | < 100 |
Recommended actuator | BPS 260-1, BPS 260-2 |
|
Mechanical data |
|
Design of electrical connection | Pre-wired cable with connector M12, angled, 4-pole |
Cable length | 2 |
Conductors | 2 x 0,23 |
AWG-Number | 23 |
mechanical installation conditions | quasi-flush |
Ensured switch distance ON Sao | 5 mm |
Ensured switch distance OFF Sar | 15 mm |
Repeat accuracy R R | R ≤ 0,1 x Sao |
notice | Axial misalignment The safety sensor and the actuator tolerate a horizontal and vertical misalignment to each other. The possible misalignment depends on the distance of the active surfaces of the sensor and the actuator. The sensor is active in the tolerance range. |
Type of actuation | Magnet |
Direction of motion | head-on with regard to the active surface |
restistance to shock | 30 g / 11 ms |
Resistance to vibration | 10 … 55 HZ, Amplitude 1 mm |
Door hinge | right |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +60 |
Storage and transport temperature |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +70 |
Protection class | IP67 to IEC/EN 60529 |
Air clearances and creepage distances To IEC/EN 60664-1 |
- Rated impulse withstand voltage Uimp | 0,8 kV |
- Rated insulation voltage Ui | 32 VDC |
- Overvoltage category | III |
- Degree of pollution | 3 |
|
Electrical data - AS interface |
|
AS-i Supply voltage | 26.5 … 31.6 VDC, Protection against polarity reversal |
AS-i operating current | ≤ 50 |
AS-i Device insulation | internally short-circuit proof |
AS-i Specification |
- version | V 2.1 |
- Profile | S-0.B.F.E |
- IO-Code | 0x0 |
- ID-Code | 0xB |
- ID-Code1 | 0xF |
- ID-Code2 | 0xE |
AS-i Inputs |
- Channel 1 | Data bits DI 0/DI 1= dynamic code transmission |
- Channel 2 | Data bits DI 2/DI 3= dynamic code transmission |
AS-i Outputs | DO 0 … DO 3 not used |
AS-i Parameter bits | P0 … P3 not used |
AS-i input module address | 0 |
- Default on address 0, programmable via the AS-Interface Master or Hand-held programming device |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
AS-i LED switching conditions display |
(1) green/red LED (AS-i duo LED) | Supply voltage / Communication error / slave address = 0 |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 36 |
- Height of sensor | 26 |
- Length of sensor | 13 |
|
Pin assignment |
|
1 | AS-i + |
2 | None |
3 | AS-i − |
4 | None |
|
Included in delivery |
|
Actuators must be ordered separately. |
|
Diagram |
|

Note Diagram
positive break NC contact
active
no active
Normally-open contact
Normally-closed contact |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
19.02.2019 -
20:47:35h Kasbase 3.3.0.F.64I |