Ordering details |
|
NOTICE: Not available! (Replacement: SLC 425I) |
Product type description | SLC 415I-E/R1210-40-12-H |
Article number | 101186037 |
EAN Code | 4030661343358 |
eCl@ss | 27-27-27-04 |
|
Approval |
|
Approval | TÜV
USA/CAN |
|
Global Properties |
|
Permanent light | SLC 415I Sicherheits-Lichtvorhang |
Standards | IEC/EN 61496-1/-2 |
Compliance with the Directives (Y/N)  | Yes |
Operating resource protection class | Protection class 3 |
Safety type in accordance with IEC 61496-1 | 4 |
Materials |
- Material of the housings | Aluminium |
Beam coding (Y/N) | Yes |
Protection field height | 1210 |
Range of the protection field | 0 - 60000 |
Reaction time | 21 |
Wave length of the sensors | 950 nm |
Fade-out is possible (Y/N) | No |
Override possible (Y/N) | Yes |
reduced resolution (Y/N) | No |
Clock control possible (Y/N) | No |
Muting possible (Y/N) | Yes |
Restart block (Y/N) | Yes |
Master/slave function | No |
Cascadable (Y/N) | No |
Monitoring function of downstream devices (Y/N) | Yes |
Recommended safety-monitoring module | SCR 402R-301 AZR 311 TL AST LC ST-AS |
|
Mechanical data |
|
Detection ability for test bodies | 40 |
Number of beams | 40 |
Design of electrical connection | Connector |
- Wiring of the transmitter | connector plug M12, 5-pole |
- Wiring of the receiver | connector plug M23, 19-pole |
- Wiring of the muting sensors | connector socket 2x M12, 5-pole |
Cable length | max. 100 m |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | 0 °C |
- Max. environmental temperature | +55 °C |
Storage and transport temperature |
- Min. Storage and transport temperature | −20 °C |
- Max. Storage and transport temperature | +70 °C |
Protection class | IP65 to IEC/EN 60529 |
|
Electrical data |
|
Design of output switching element OSSD | PNP |
Power consumption |
- Power consumption Transmitter | 3 |
- Power consumption Receiver | 6 |
Voltage type | DC |
Switching voltage of the OSSD in high state | 24 V ± 20% |
|
Outputs |
|
Max. output current at secured output | 500 mA |
|
Electrical data - Safety outputs |
|
Number of secure semi-conductor outputs | 2 piece |
Number of secure outputs with contact | 0 piece |
|
Electrical data - Diagnostic output |
|
Number of semi-conductor outputs with signaling function |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
- Status and diagnostics |
- 7-segment display |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 60 mm |
- Height of sensor | 1336 |
- Length of sensor | 50 mm |
|
notice |
|
In case of failure (interruption of the 0 V supply) the maximum leakage current is 0,3 mA. |
2 or 4 muting sensors can be connected. |
The muting sensors (e.g. LF 50) must be ordered separately. |
|
Included in delivery |
|
Delivery scope of disposable system | Transmitter + receiver, Mounting angle, T-slot nuts |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
15.02.2019 -
20:34:28h Kasbase 3.3.0.F.64I |