Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
 Add Product to the basket. 
SLG 410-E/R0500-02-RFS
• Control Category 4
NOTICE: Not available! (Replacement: SLG 420)

 
 
Ordering details
 
NOTICE: Not available! (Replacement: SLG 420)
Product type descriptionSLG 410-E/R0500-02-RFS
Article number101185970
EAN Code4030661342788
eCl@ss27-27-27-03
 
Approval
 
Approval TÜV
USA/CAN
 
Global Properties
 
Permanent lightSLG 410 Sicherheits-Lichtgitter
StandardsIEC/EN 61496-1/-2
Compliance with the Directives (Y/N) Yes
Operating resource protection classProtection class 3
Safety type in accordance with IEC 61496-14
Materials
- Material of the housingsAluminium
Weight3785
Beam coding (Y/N)Yes
Beam number2
Beam distance500
Protection field height510
Range of the protection field0 - 18000
Reaction time6
Wave length of the sensors950 nm
Override possible (Y/N)No
Muting possible (Y/N)No
Restart block (Y/N)No
Master/slave functionslave
Cascadable (Y/N)Yes
Preliminary failure signal possible (Y/N)No
Design of multi-ray photoelectric barrierTransmitter and receiver, separated
Monitoring function of downstream devices (Y/N)No
Recommended safety-monitoring moduleSCR 402R-301
AZR 311 TL
AST LC ST-AS
 
Mechanical data
 
Design of electrical connectionConnector
- Wiring of the transmitterconnector plug M12, 5-pole
- Wiring of the receiverconnector plug M12, 5-pole
Cable lengthmax. 50 m
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature0 °C
- Max. environmental temperature+55 °C
Storage and transport temperature
- Min. Storage and transport temperature−20 °C
- Max. Storage and transport temperature+70 °C
Protection classIP65 to IEC/EN 60529
 
Electrical data
 
Design of output switching element OSSDPNP
Power consumption
- Power consumption Transmitter2 W
- Power consumption Receiver3 W
Voltage typeDC
Switching voltage of the OSSD in high state24 V ± 20%
 
Outputs
 
Max. output current at secured output500 mA
 
Electrical data - Safety outputs
 
Number of secure semi-conductor outputs2 piece
Number of secure outputs with contact0 piece
 
Electrical data - Diagnostic output
 
Number of semi-conductor outputs with signaling function0 piece
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
- Status and diagnostics
- 7-segment display
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor45 mm
- Height of sensor711
- Length of sensor35 mm
 
notice
 
In case of failure (interruption of the 0 V supply) the maximum leakage current is 0,3 mA.
 
Included in delivery
 
Delivery scope of disposable systemTransmitter + receiver, Mounting angle, T-slot nuts

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 17.02.2019 - 22:37:08h Kasbase 3.3.0.F.64I