Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Safety sensors  ->  BNS 260  ->  BNS 260-02/01ZG-L
• Thermoplastic enclosure
• Small body
• Concealed mounting possible
• 26 mm x 36 mm x 13 mm
• Long life
• no mechanical wear
• Insensitive to transverse misalignment
• Insensitive to soiling
• Pre-wired cable

 
Preferred typ
 
Ordering details
 
Product type descriptionBNS 260-02/01ZG-L
Article number101184390
EAN Code4030661321905
eCl@ss27-27-24-02
 
Approval
 
Approval BG
USA/CAN
EAC
 
Classification
 
StandardsEN ISO 13849-1
B10d Normally-closed contact (NC)25.000.000
- noticeat max. 20% contact load
Mission time20 Years
notice
 
Global Properties
 
Permanent lightBNS 260
StandardsIEC 60947-5-3, BG-GS-ET-14
Compliance with the Directives (Y/N) Yes
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
- Material of the cable mantlePVC
Weight60
Coding available (Y/N)Yes
Monitoring function of downstream devices (Y/N)No
Prerequisite evaluation unit
Recommended safety-monitoring module
Recommended actuatorBPS 260
 
Mechanical data
 
Design of electrical connectionCable
Cable length1
Conductors6 x 0,25
AWG-Number
mechanical installation conditionsquasi-flush
Active area
Ensured switch distance ON Sao5 mm
Ensured switch distance OFF Sar15 mm
noticeAxial misalignment
The safety sensor and the actuator tolerate a horizontal and vertical misalignment to each other. The possible misalignment depends on the distance of the active surfaces of the sensor and the actuator. The sensor is active in the tolerance range.
Type of actuationMagnet
Direction of motionhead-on with regard to the active surface
restistance to shock30 g / 11 ms
Resistance to vibration10 … 55 HZ, Amplitude 1 mm
Door hingeleft
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25 °C
- Max. environmental temperature+70 °C
Storage and transport temperature
- Min. Storage and transport temperature−25 °C
- Max. Storage and transport temperature+70 °C
Protection classIP67
 
Electrical data
 
Integrated Safety monitoring module available (Y/N)No
Cross circuit/short circuit recognition possible (Y/N)Yes
Voltage typeVDC
Switch frequencymax. 5 HZ
Switching voltagemax. 24 VDC
Switching currentmax. 10 mA
Switching capacitymax. 240 mW
 
Outputs
 
Design of control output
Number of shutters0
Number of openers3
Design of output signal switching device
 
Electrical data - Safety outputs
 
Number of secure semi-conductor outputs0
Number of secure outputs with contact2
 
Electrical data - Diagnostic output
 
Number of semi-conductor outputs with signaling function0
Number of outputs with signaling function that already have a contact1
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
- The LED is illuminated when the guard is closed.
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor26 mm
- Height of sensor36 mm
- Length of sensor13 mm
 
notice
 
Contact symbols shown for the closed condition of the guard device.
The contact configuration for versions with or without LED is identical.
Contact S21-S22 und S11-S12 must be integrated in the safety circuit
 
Included in delivery
 
Actuators must be ordered separately.
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.