Notes Switch travel diagram Contact closed Contact open Setting range Break point Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel
• Thermoplastic enclosure • Small body • Concealed mounting possible • 26 mm x 36 mm x 13 mm • Long life • no mechanical wear • Insensitive to transverse misalignment • Insensitive to soiling • Pre-wired cable
Axial misalignment The safety sensor and the actuator tolerate a horizontal and vertical misalignment to each other. The possible misalignment depends on the distance of the active surfaces of the sensor and the actuator. The sensor is active in the tolerance range.
Type of actuation
Magnet
Direction of motion
head-on with regard to the active surface
restistance to shock
30 g / 11 ms
Resistance to vibration
10 … 55 HZ, Amplitude 1 mm
Door hinge
left
Ambient conditions
Ambient temperature
- Min. environmental temperature
−25 °C
- Max. environmental temperature
+70 °C
Storage and transport temperature
- Min. Storage and transport temperature
−25 °C
- Max. Storage and transport temperature
+70 °C
Protection class
IP67
Electrical data
Integrated Safety monitoring module available (Y/N)
No
Cross circuit/short circuit recognition possible (Y/N)
Yes
Voltage type
VDC
Switch frequency
max. 5 HZ
Switching voltage
max. 24 VDC
Switching current
max. 10 mA
Switching capacity
max. 240 mW
Outputs
Design of control output
Number of shutters
0
Number of openers
3
Design of output signal switching device
Electrical data - Safety outputs
Number of secure semi-conductor outputs
0
Number of secure outputs with contact
2
Electrical data - Diagnostic output
Number of semi-conductor outputs with signaling function
0
Number of outputs with signaling function that already have a contact
1
LED switching conditions display
LED switching conditions display (Y/N)
Yes
- The LED is illuminated when the guard is closed.
ATEX
Explosion protection categories for gases
None
Explosion protected category for dusts
None
Dimensions
Dimensions of the sensor
- Width of sensor
26 mm
- Height of sensor
36 mm
- Length of sensor
13 mm
notice
Contact symbols shown for the closed condition of the guard device.
The contact configuration for versions with or without LED is identical.
Contact S21-S22 und S11-S12 must be integrated in the safety circuit
Included in delivery
Actuators must be ordered separately.
Diagram
Note Diagram positive break NC contact active no active Normally-open contact Normally-closed contact
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
16.02.2019 -
12:16:28h Kasbase 3.3.0.F.64I