Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Foot switch  ->  2F 232  ->  T2FH 232-20HD/20HD
• Metal enclosure
• double-pedal type
• 2 cable entries M 25 x 1.5
• High level of stability
• Low operating height of pedal
• 2 contacts per pedal
• 3-phase actuation with pressure point
• Protective shield with wide opening

 
 
Ordering details
 
Product type descriptionT2FH 232-20HD/20HD
Article number101182023
EAN Code4030661326696
eCl@ss27-37-12-18
 
Approval
 
Approval
 
Global Properties
 
Permanent light2F 232
StandardsEN 60947-5-1, DIN VDE 0660-200, BG-GS-ET-15
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)No
Materials
- Material of the housingsAluminium
- Material of the coverAluminium
- Material of the protective shieldAluminium
- Material of the pedalPlastic, glass-fibre reinforced thermoplastic
Housing coatingpowder-coated
Colouring
- Enclosure colorRAL 9006 (White aluminum)
Weight3000
with start/stop function (Y/N)No
Suitable for EMERGENCY-OFF (Y/N)No
Protection hood (Y/N)Yes
3-phase actuation with pressure point (Y/N)Yes
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section
- Max. Cable section1 x 2.5
Mechanical life> 1.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
Latching (Y/N)No
Probing possible (Y/N)Yes
Locking (Y/N)No
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+70
Protection type IPIP65 to IEC/EN 60529
 
Electrical data
 
Design of control elementNormally open contact (NO)
Switching principleSlow action
Number of shutters ( per pedal)2
Number of openers ( per pedal)0
Rated impulse withstand voltage6
Rated insulation voltage500
Thermal test current10 A
Utilisation categoryAC-15: 230 V / 4 A,
DC-13: 24 V / 1 A
Max. fuse rating6 A gG D-fuse
 
Dimensions
 
Dimensions
- Width295
- Height189
- Depth274
 
notice
 
The pressure point can only be ordered for 2 NO or 4 NO contacts (20 or 40) per pedal and is exclusively available with slow action (T). The pressure point must be indicated separately for each contact type,
e.g. TFH 232-11hd or T2FH 232-11hd/11hd
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 23.04.2019 - 14:52:05h Kasbase 3.3.0.F.64I