Ordering details |
|
Product type description | SRB 202MSL-24V |
Article number | 101181998 |
EAN Code | 4250116202577 |
eCl@ss | 27-37-19-01 |
|
Approval |
|
Approval | USA/CAN |
|
Classification |
|
Standards | EN ISO 13849-1, IEC 61508, EN 60947-5-1 |
PL | up e (STOP 0) |
Control category | up 4 (STOP 0) |
DC | 99% (STOP 0) |
CCF | >65 points |
PFH value | ≤ 2,0 x 10-8/h (STOP 0) |
SIL | up 3 (STOP 0) |
Mission time | 20 Years |
- notice | The PFH value is applicable for the combinations listed in the table for contact load (K) (current through enabling paths) and switching cycle number (n-op/y). In case of 365 operating days per year and a 24-hour operation, this results in the specified switching cycle times (t-cycle) for the relay contacts. Diverging applications on request.
 |
|
Global Properties |
|
Permanent light | SRB 202MSL |
Standards | IEC/EN 60204-1, EN 60947-5-1, EN ISO 13849-1, IEC 61508 |
Compliance with the Directives (Y/N)  | Yes |
Climatic stress | EN 60068-2-78 |
Mounting | snaps onto standard DIN rail to EN 60715 |
Terminal designations | IEC/EN 60947-1 |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic, ventilated |
- Material of the contacts | AgSn0, Ag-Ni, self-cleaning, positive action |
Weight | 400 |
Start conditions | Automatic with Muting sensors |
Start input (Y/N) | No |
Feedback circuit (Y/N) | Yes |
Start-up test (Y/N) | No |
Reset after disconnection of supply voltage (Y/N) | Yes |
Automatic reset function (Y/N) | Yes |
Reset with edge detection (Y/N) | No |
Pull-in delay |
- ON delay with automatic start | typ. 200 ms |
Drop-out delay |
- Drop-out delay in case of power failure | typ. 60 ms |
- Drop-out delay in case of emergency stop | typ. 17 ms / ≤ 20 ms |
|
Mechanical data |
|
Connection type | Screw connection |
Cable section |
- Min. Cable section | 0,25 |
- Max. Cable section | 2.5 |
Pre-wired cable | rigid or flexible |
Tightening torque for the terminals | 0,6 |
Detachable terminals (Y/N) | Yes |
Mechanical life | 10.000.000 operations |
Electrical lifetime | Derating curve available on request |
restistance to shock | 30 g / 11 ms |
Resistance to vibration To EN 60068-2-6 | 10…55 HZ, Amplitude 0,35 mm, ± 15 % |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −25 °C |
- Max. environmental temperature | +45 °C |
Storage and transport temperature |
- Min. Storage and transport temperature | −40 °C |
- Max. Storage and transport temperature | +85 °C |
Protection class |
- Protection class-Enclosure | IP40 |
- Protection class-Terminals | IP20 |
- Protection class-Clearance | IP54 |
Air clearances and creepage distances To IEC/EN 60664-1 |
- Rated impulse withstand voltage Uimp | 4 kV |
- Overvoltage category | III To VDE 0110 |
- Degree of pollution | 2 To IEC/EN 60664-1 |
|
Electromagnetic compatibility (EMC) |
|
EMC rating | conforming to EMC Directive |
|
Electrical data |
|
Rated DC voltage for controls |
- Max. rated DC voltage for controls | 20.4 |
- Max. rated DC voltage for controls | 28.8 |
Rated AC voltage for controls, 50 Hz |
- Min. rated AC voltage for controls, 50 Hz | - |
- Max. rated AC voltage for controls, 50 Hz | - |
Rated AC voltage for controls, 60 Hz |
- Min. rated AC voltage for controls, 60 Hz | - |
- Max. rated AC voltage for controls, 60 Hz | - |
Contact resistance | max. 100 mΩ |
Power consumption | 5.6, plus Signalling outputs |
Type of actuation | DC |
Rated operating voltage Ue | 24 VDC −15% / +20%, residual ripple max. 10% |
Frequency range | 50 / 60 HZ |
Electronic protection (Y/N) | Yes |
Fuse rating for the operating voltage | Internal electronic trip, tripping current > 1.25 A, Reset after approximately 1 second/s |
|
Inputs |
|
Monitored inputs |
- Short-circuit recognition (Y/N) | Yes |
- Wire breakage detection (Y/N) | Yes |
- Earth connection detection (Y/N) | Yes |
Number of shutters | 0 piece |
Number of openers | 2 piece |
Cable length | 1500 m with 1.5 mm²; 2500 m with 2.5 mm² |
Conduction resistance | max. 40 Ω |
|
Outputs |
|
Stop category | 0 |
Number of safety contacts | 2 piece |
Number of auxiliary contacts | 0 piece |
Number of signalling outputs | 2 piece |
Switching capacity |
- Switching capacity of the safety contacts | max. 24 VDC, 4 A ohmic (inductive in case of appropriate protective wiring) |
- Switching capacity of the signaling/diagnostic outputs | L54/L84: max. 50 mA LA1/LA2: max. 500 mA; min. 150 mA |
Fuse rating |
- Protection of the safety contacts | 4 A slow blow |
- Fuse rating for the signaling/diagnostic outputs | T 0,5 A slow blow |
Utilisation category To EN 60947-5-1 | DC-13: 24 V / 2 A |
Number of undelayed semi-conductor outputs with signaling function | 0 piece |
Number of undelayed outputs with signaling function (with contact) | 2 piece |
Number of delayed semi-conductor outputs with signaling function. | 0 piece |
Number of delayed outputs with signalling function (with contact). | 0 piece |
Number of secure undelayed semi-conductor outputs with signaling function | 0 piece |
Number of secure, undelayed outputs with signaling function, with contact. | 2 piece |
Number of secure, delayed semi-conductor outputs with signaling function | 0 piece |
Number of secure, delayed outputs with signaling function (with contact). | 0 piece |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
Number of LED´s | 8 |
LED switching conditions display |
- The integrated LEDs indicate the following operating states. |
- Position relay K1 |
- Position relay K4 |
- Position relay K3 |
- Position relay K5 |
- Position relay K2 |
- Supply voltage |
- Internal operating voltage Ui |
- Position of the muting signalling device LA |
|
Miscellaneous data |
|
Applications | muting function |
|
Dimensions |
|
Dimensions |
- Width | 45 mm |
- Height | 100 mm |
- Depth | 121 mm |
|
notice |
|
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
|
notice - Wiring example |
|
The example shows a 2-channel control of 2 muting sensors and an external master reset button. |
Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. |
(H2) = Feedback circuit |
The control recognises cross-short, cable break and earth leakages in the monitoring circuit. |
F1 = Electronic fuse |
The wiring diagram is shown with non-actuated muting sensors and in de-energised condition. |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
17.02.2019 -
22:29:47h Kasbase 3.3.0.F.64I |