Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Monitoring of BNS range magnetic safety sensors
• 4 safety contacts, STOP 0
• 2 Signalling outputs

 
 
Ordering details
 
Product type descriptionAES 2565
Article number101181688
EAN Code4030661323176
eCl@ss27-37-19-01
 
Approval
 
Approval BG
USA/CAN
EAC
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508
PLup d
Control categoryup 3
PFH value1.0 x 10-7/h
- noticeup to max. 50.000 switching cycles/year and at max. 80% contact load
SILup 2
Mission time20 Years
 
Global Properties
 
Permanent lightAES 256x
StandardsIEC/EN 60204-1, EN 60947-5-1, IEC 60947-5-3, IEC 61508, BG-GS-ET-14, BG-GS-ET-20
Compliance with the Directives (Y/N) Yes
Climatic stressEN 60068-2-3, BG-GS-ET-14
Mountingsnaps onto standard DIN rail to EN 60715
Terminal designationsIEC/EN 60947-1
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
- Material of the contactsAg-Ni, 0,2 µm gold flashed
Weight300
Start input (Y/N)No
Feedback circuit (Y/N)Yes
Start-up test (Y/N)No
Reset after disconnection of supply voltage (Y/N)Yes
Automatic reset function (Y/N)Yes
Reset with edge detection (Y/N)No
Pull-in delay
- ON delay with automatic startadjustable 0,1 / 1.0 s
Drop-out delay
- Drop-out delay in case of emergency stop< 50
 
Mechanical data
 
Connection typeScrew connection
Cable section
- Min. Cable section0,2
- Max. Cable section2.5
Pre-wired cablerigid or flexible
Tightening torque for the terminals0,6
Detachable terminals (Y/N)No
Mechanical life20.000.000 operations
Electrical lifetime150.000 operations for 230 VAC, 5 A (cos φ = 1)
restistance to shock30 g / 11 ms
Resistance to vibration To EN 60068-2-610…55 HZ, Amplitude 0,35 mm, ± 15 %
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature0
- Max. environmental temperature+55
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+70
Protection class
- Protection class-EnclosureIP40
- Protection class-TerminalsIP20
- Protection class-ClearanceIP54
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp4.8 kV
- Overvoltage categoryIII To VDE 0110
- Degree of pollution2 To VDE 0110
 
Electromagnetic compatibility (EMC)
 
EMC rating10 V/m
 
Electrical data
 
Rated DC voltage for controls
- Max. rated DC voltage for controls20.4
- Max. rated DC voltage for controls253 VDC
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz20.4 VAC
- Max. rated AC voltage for controls, 50 Hz253 VAC
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz20.4 VAC
- Max. rated AC voltage for controls, 60 Hz253 VAC
Contact resistancemax. 100 mΩ
Power consumption5
Type of actuationDC
Switch frequency3
Rated insulation voltage Ui250 V
Rated operating voltage Ue24 … 230 VAC/DC
Thermal test current Ithe6 A
Operating current Ie0,3 A
Electronic protection (Y/N)No
 
Inputs
 
Monitored inputs
- Short-circuit recognition (Y/N)Yes
- Wire breakage detection (Y/N)Yes
- Earth connection detection (Y/N)No
Number of shutters2
Number of openers2
Input resistanceapprox. 4000 Ω at GND
Input signal "1"10 … 30 VDC
Input signal "0"0 … 2 VDC
Cable length1000 m with 0,75 mm² (for Rated voltage)
 
Outputs
 
Stop category0
Number of safety contacts4
Number of auxiliary contacts1
Number of signalling outputs2
Switching capacity
- Switching capacity of the safety contactsmin. 10 mA, max. 6 A
- Switching capacity of the signaling/diagnostic outputsY1, Y2: max. 100 mA
Fuse rating
- Protection of the safety contacts6 A gG D-fuse
- Fuse rating for the signaling/diagnostic outputsshort-circuit proof
Signalling outputY1: Authorized operation, safety contacts on
; 2 Y: Error, safety contacts off
Utilisation category To EN 60947-5-1AC-15: 230 V / 3 A
DC-13: 24 V / 2 A
Number of undelayed semi-conductor outputs with signaling function2
Number of undelayed outputs with signaling function (with contact)1
Number of delayed semi-conductor outputs with signaling function.0
Number of delayed outputs with signalling function (with contact).0
Number of secure undelayed semi-conductor outputs with signaling function0
Number of secure, undelayed outputs with signaling function, with contact.0
Number of secure, delayed semi-conductor outputs with signaling function0
Number of secure, delayed outputs with signaling function (with contact).0
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Number of LED´s1
 
Integral system diagnosis $missingShortName$
 
Integral system diagnosis ISD
- The following faults are registered by the safety monitoring modules and indicated by ISD
- Failure of door contacts to open or close
- Cross-wire or short-circuit monitoring of the switch connections
- Interruption of the switch connections
- Failure of the safety relay to pull-in or drop-out
- Fault on the input circuits or the relay control circuits of the safety monitoring module
 
Miscellaneous data
 
Applications Safety sensor
Guard system
 
Dimensions
 
Dimensions
- Width45 mm
- Height100 mm
- Depth121 mm
 
notice
 
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
 
notice - Wiring example
 
To secure 2 guard doors up to PL d and Category 3
Monitoring a guard door using vier position switches with safety function.
The feedback circuit monitors the positions of the positive-guided NC contacts on the conactors K3 and K4.
If neither start button nor feedback circuit are connected, a jumper connection must be mounted between X1 and X2.
Start push button A start push button (NO) can optionally be connected into the feedback circuit. With the guard door closed, the enabling paths are then not closed until the start push button has been operated.
If neither start button nor feedback circuit are connected, a jumper connection must be mounted between X1 and X2.
Expansion of the enable delay time
The enable delay time can be increased from 0,1 s to 1 s by mounting a jumper connection between the terminals X7 and X8.
The wiring diagram is shown with guard doors closed and in de-energised condition.
The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 19.04.2019 - 20:49:54h Kasbase 3.3.0.F.64I