|  Preferred typ |
|
Ordering details |
|
Product type description | CSS 12-34-V-SD-M-ST |
Article number | 101181067 |
EAN Code | 4030661314907 |
eCl@ss | 27-27-24-01 |
|
Approval |
|
Approval | BG
USA/CAN
EAC |
|
Classification |
|
Standards | EN ISO 13849-1, IEC 61508, IEC 60947-5-3 |
PL | bis e |
Control category | bis 4 |
PFH | 3.6 x 10-9/h |
SIL | 3 bis |
Mission time | 20 Years |
Classification | PDF-M |
|
Global Properties |
|
Permanent light | CSS 34 |
Standards | IEC 60947-5-3 |
Compliance with the Directives (Y/N)  | Yes |
Suitable for safety functions (Y/N) | Yes |
Function | Sensor for series wiring |
Series-wiring | up to 31 components |
Length of the sensor chain | max. 200 m |
Active principle | inductive |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic |
- Material of the active surface | Plastic, glass-fibre reinforced thermoplastic |
Housing construction form | Block |
Weight | 140 |
Input for enabling pushbutton, suitable for automatic start (Y/N) | No |
Input for reset pushbutton, with edge monitoring (Y/N) | No |
Diagnostic output (Y/N) | Yes |
Reaction time | < 30 |
Duration of risk | < 60 |
Cascadable (Y/N) | Yes |
Recommended actuator | CST 34-V-1, CST 34-S-2, CST 34-S-3, CST 180-1, CST 180-2 |
|
Mechanical data |
|
Design of electrical connection | connector plug M12, 8-pole |
mechanical installation conditions | not flush |
Actuating planes | Actuation from top |
Active area | front |
Switch distance Sn | 10 mm / 12 mm / 15 mm |
- Actuator CST 34-V-1 | 12 |
- Actuator CST 34-S-2 | 10 |
- Actuator CST 34-S-3 | 15 |
- Actuator CST 180-1 / CST 180-2 | 12 |
Ensured switch distance ON Sao | 8 mm / 10 mm / 13 mm |
- Actuator CST 34-V-1 | 10 |
- Actuator CST 34-S-2 | 8 |
- Actuator CST 34-S-3 | 13 |
- Actuator CST 180-1 / CST 180-2 | 10 |
Ensured switch distance OFF Sar | 15 mm / 16 mm / 18 mm |
- Actuator CST 34-V-1 | 15 |
- Actuator CST 34-S-2 | 16 |
- Actuator CST 34-S-3 | 18 |
- Actuator CST 180-1 / CST 180-2 | 16 |
hysteresis | max. 1.5 mm |
Repeat accuracy R R | ≤ 0,5 mm |
notice | Axial offset: The front face allows for an axial misalignment (z) of max. ± 8 mm. see drawing: Operating principle |
restistance to shock | 30 g / 11 ms |
Resistance to vibration | 10 … 55 HZ, Amplitude 1 mm |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +70 |
Storage and transport temperature |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +85 |
Protection class | IP65, IP67 to IEC/EN 60529 |
Protection rating | II |
Air clearances and creepage distances To IEC/EN 60664-1 |
- Rated impulse withstand voltage Uimp | 0,8 kV |
- Overvoltage category | III |
- Degree of pollution | 3 |
|
Electromagnetic compatibility (EMC) |
|
EMC rating | to IEC 61000-6-2 |
Interfering radiation | to IEC 61000-6-4 |
|
Electrical data |
|
Cross circuit/short circuit recognition possible (Y/N) | Yes |
Voltage type | DC |
Switch frequency | 3 |
Rated insulation voltage Ui | 32 VDC |
Rated operating voltage Ue (stabilised PELV) |
Operating current Ie | 0,6 A |
No-load current I0 | 0,1 A |
Required rated short-circuit current | 100 A |
Device insulation (Circuit breaker) | 2 A |
notice | The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current |
|
Electrical data - Safety inputs |
|
Safety inputs | X1 and X2 |
|
Electrical data - Safety outputs |
|
Safety outputs | Y1 and Y2 |
Fuse rating | short-circuit proof |
Design of control output | p-type |
Number of secure semi-conductor outputs | 2 |
Max. output current at secured output | 0,25 A |
Rated operating voltage | min. (Ue − 1 V) |
Residual current Ir | ≤ 0,5 mA |
Operating current Ie | max. 0,25 A |
- Ambient temperature: −25 °C … +70 °C | ≤ 0,1 A |
Minimum operating current Im | 0,5 mA |
- Ambient temperature: −25 °C … +65 °C | ≤ 0,25 A |
Utilisation category | DC-12: 24 V / 0,25 A DC-13: 24 V / 0,25 A |
Voltage drop Ud | < 1 V |
|
Electrical data - Diagnostic output |
|
Serial diagnostics (Y/N) | Yes |
Fuse rating | short-circuit proof |
Design of control output | p-type |
Number of semi-conductor outputs with signaling function | 1 |
Rated operating voltage | min. (Ue − 5 V) |
Operating current Ie | max. 0,05 A |
Voltage drop Ud | < 5 V |
Utilisation category | DC-12: 24 V / 0,05 A DC-13: 24 V / 0,05 A |
Wiring capacitance for serial diagnostics | max. 50 nF |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
Number of LED´s | 3 |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 27 |
- Height of sensor | 108.2 |
- Length of sensor | 35 |
|
Pin assignment |
|
1 - A1 Ue | (1) |
2 - X1 Safety input 1 | (2) |
3 - A2 GND | (3) |
4 - Y1 Safety output 1 | (4) |
5 - SD serial diagnostic output | (5) |
6 - X2 Safety input 2 | (6) |
7 - Y2 Safety output 2 | (7) |
8 - IN serial diagnostic input | (8) |
|
notice |
|
Requirements for the safety monitoring module | 2-channel safety input, suitable for p-type sensors with NO function. The safety monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0,5 ms. The safety monitoring module does not need to have a cross-wire short monitoring function. |
|
Included in delivery |
|
Actuators must be ordered separately. |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
20.02.2019 -
22:40:39h Kasbase 3.3.0.F.64I |