Notes Switch travel diagram Contact closed Contact open Setting range Break point Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel
All indications about the cable section are including the conductor ferrules.
Cable section
- Min. Cable section
0,5, rigid 0,5, flexible
- Max. Cable section
2.5, rigid 1.5, flexible
Assembly
pluggable
Mounting flange position
2
Mechanical life / contact element
10.000.000 operations
Switching frequency
1200
restistance to shock
110 g / 4 ms
resistant to vibration
> 20 g / 10 … 200 HZ
Bounce duration (100 mm/s)
< 5 ms
positive break travel
2
Contact opening
2
Ambient conditions
Ambient temperature
- Min. environmental temperature
−25
- Max. environmental temperature
+80
Protection class
- Protection class-Terminals
IP20
- Protection class switching compartments
IP40
Electrical data
Design of control element
Opener (NC), Normally open contact (NO)
Switching principle
Slow action
Number of shutters
1
Number of openers
1
Rated insulation voltage Ui
400 V
Thermal test current Ithe
10 A
Utilisation category
AC-15: 230 V / 8 A DC-13: 24 V / 5 A
Max. fuse rating
10 A gG D-fuse slow blow
Test voltage (enclosed)
2500 VAC
Suitable for low-voltages
≥ 5 V, 3.2 mA
Dimensions
Dimensions
- Width
10 mm
- Length
46 mm
- Depth
60 mm
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
16.02.2019 -