Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Metal enclosure
• Wide range of alternative actuators
• Good resistance to oil and petroleum spirit
• 40,5 mm x 76 mm x 38 mm
• Actuator heads can be repositioned by 4 x 90°
• 1 Cable entry M 20 x 1.5
• Design to EN 50041

 
 
Ordering details
 
Product type descriptionT4V7H 335-11Z-2138 - Ordering suffix
Article number101172195
EAN Code4030661300375
eCl@ss27-27-26-01
 
Approval
 
Approval USA/CAN
CCC
EAC
 
Classification
 
StandardsEN ISO 13849-1
B10d Normally-closed contact (NC)20.000.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightT 335 Rollenschwenkhebel 7H 2138
StandardsEN 60947-5-1, BG-GS-ET-15
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Materials
- Material of the housingsAluminium
- Lever materialMetal film
- Roller materialPlastic
- Material of the contactsSilver
Housing coatingpainted
Housing construction formNorm construction design
Weight282
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section0,75
- Max. Cable section2.5
Mechanical life30.000.000 operations
Switching frequencymax. 5000 /h
noticeAll indications about the cable section are including the conductor ferrules.
Design of actuating elementRoller lever
actuating torquemin. 31 Ncm
Bounce duration< 2
Switchover timein accordance with actuating speed
Actuating speed with actuating angle 30° to switch axis
- Min. Actuating speed
- Max. Actuating speed2.5 m/s
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−30 °C
- Max. environmental temperature+80 °C
Protection classIP67
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
Switching principleSlow action
- positive break NC contact
Number of auxiliary contacts1
Number of safety contacts1
Rated impulse withstand voltage Uimp6 kV
Rated insulation voltage Ui500 V
Thermal test current Ithe10 A
Utilisation categoryAC-15: 230 V / 4 A,
DC-13: 24 V / 4 A
Required rated short-circuit current1000 A
Max. fuse rating6 A gG D-fuse
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor40.5 mm
- Height of sensor173.5 mm
- Length of sensor57.25 mm
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Switch travel diagram
 


Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: T4V7H 335-11z-2138-1637
...-1637 0,3 µm gold-plated contacts

...-NPT Cable entry NPT 1/2“

...-ST M12 connector with A-coding
Rated impulse withstand voltage Uimp: 0,8 kV
Rated insulation voltage Ui: 50 V
Rated operating voltage Ue: 50 V
Operating current Ie: 4 A
Caution! The versions with connector may only be used in PELV circuits to EN 60204-1.

...-2310 M12 connector with B-coding
Rated impulse withstand voltage Uimp: 0,8 kV
Rated insulation voltage Ui: 50 V
Rated operating voltage Ue: 50 V
Operating current Ie: 4 A
Caution! The versions with connector may only be used in PELV circuits to EN 60204-1.


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.