Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Metal enclosure
• Good resistance to oil and petroleum spirit
• 30 mm x 88,5 mm x 30 mm
• Actuator heads can be repositioned by 4 x 90°
• 1 Cable entry M 20 x 1.5

 
 
Ordering details
 
Product type descriptionT3C 235-02Z - Ordering suffix
Article number101171209
EAN Code4030661298740
eCl@ss27-27-26-01
 
Approval
 
Approval BG
USA/CAN
CCC
EAC
 
Classification
 
StandardsEN ISO 13849-1
B10d Normally-closed contact (NC)20.000.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightT.C 235 Linksausführung
StandardsEN 60947-5-1, BG-GS-ET-15
Compliance with the Directives (Y/N) Yes
Materials
- Material of the housingszinc die-cast
- Lever materialStainless steel
- Material of the contactsSilver
Housing coatingpainted
Weight190
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section1 x 0,75
- Max. Cable section1 x 2.5
Mechanical life> 1.000.000 operations
Switching frequencymax. 5000 /h
noticeAll indications about the cable section are including the conductor ferrules.
Design of actuating elementSwivel lever
Opening angle180 °
Positive break angle12.5 °
Positive break torque18.5 Ncm
actuator78 mm
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−30 °C
- Max. environmental temperature+80 °C
Protection classIP67
 
Electrical data
 
Design of control elementOpener (NC)
Switching principleCreep circuit element
Number of auxiliary contacts0
Number of safety contacts2
Rated impulse withstand voltage Uimp6 kV
Rated insulation voltage Ui500 V
Thermal test current Ithe10 A
Utilisation categoryAC-15: 230 V / 4 A,
DC-13: 24 V / 1 A
Max. fuse rating6 A gG D-fuse
noticeCaution! The versions with connector may only be used in PELV circuits to EN 60204-1.
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor93
- Height of sensor94.5
- Length of sensor30
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Switch travel diagram
 


Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: T3C 235-02Z-ST
...-ST M12 connector with A-coding
Rated impulse withstand voltage Uimp: 0,8 kV
Rated insulation voltage Ui: 50 V
Operating current Ie: AC-15: 50 V / 4 A
Caution! The versions with connector may only be used in PELV circuits to EN 60204-1.

...-2310 M12 connector with B-coding
Rated impulse withstand voltage Uimp: 0,8 kV
Rated insulation voltage Ui: 50 V
Operating current Ie: AC-15 50 V / 4 A
Caution! The versions with connector may only be used in PELV circuits to EN 60204-1.


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.