Ordering details |
|
Product type description | BNS 333-01YU |
Article number | 101169807 |
EAN Code | 4030661296524 |
eCl@ss | 27-27-24-02 |
|
Approval |
|
Approval | BG
EAC |
|
Classification |
|
Standards | EN ISO 13849-1 |
B10d Normally-closed contact (NC) | 20.000.000 |
- notice | at max. 20% contact load |
Mission time | 20 Years |
notice |  |
|
Global Properties |
|
Permanent light | BNS 333 |
Standards | IEC 60947-5-3, BG-GS-ET-14 |
Compliance with the Directives (Y/N)  | Yes |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic |
Weight | 145 |
Coding available (Y/N) | Yes |
Monitoring function of downstream devices (Y/N) | No |
Prerequisite evaluation unit |
Recommended safety-monitoring module |
Recommended actuator | BPS 300, BPS 303, BPS 303 SS |
|
Mechanical data |
|
• Wiring compartment |
Design of electrical connection | Screw connection |
Cable section |
- Min. Cable section | 2 x 0,75 |
- Max. Cable section | 2 x 1.5 |
AWG-Number | 15 |
mechanical installation conditions | quasi-flush |
Active area | bottom |
Ensured switch distance ON Sao | 4 mm |
Ensured switch distance OFF Sar | 14 mm |
notice | All indications about the cable section are including the conductor ferrules. |
Type of actuation | Magnet |
Direction of motion | head-on with regard to the active surface |
restistance to shock | 30 g / 11 ms |
Resistance to vibration | 10 … 55 HZ, Amplitude 1 mm |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −25 °C |
- Max. environmental temperature | +55 °C |
Storage and transport temperature |
- Min. Storage and transport temperature | −25 °C |
- Max. Storage and transport temperature | +70 °C |
Protection class | IP65 |
|
Electrical data |
|
Integrated Safety monitoring module available (Y/N) | Yes |
Cross circuit/short circuit recognition possible (Y/N) | No |
Voltage type | VAC/DC |
Switch frequency | max. 5 HZ |
Switching voltage | max. 250 V |
Switching current | max. 5 A |
Switching capacity | max. 1250 W |
|
Outputs |
|
Design of control output |
Number of shutters | 0 |
Number of openers | 1 |
Design of output signal switching device |
|
Electrical data - Safety outputs |
|
Number of secure semi-conductor outputs | 0 |
Number of secure outputs with contact | 1 |
|
Electrical data - Diagnostic output |
|
Number of semi-conductor outputs with signaling function | 0 |
Number of outputs with signaling function that already have a contact | 0 |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
- The LED is illuminated when the guard is closed. |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 52 mm |
- Height of sensor | 90 mm |
- Length of sensor | 39 mm |
|
notice |
|
Contact symbols shown for the closed condition of the guard device. |
|
Included in delivery |
|
Actuators must be ordered separately. |
|
Diagram |
|

Note Diagram
positive break NC contact
active
no active
Normally-open contact
Normally-closed contact |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
24.02.2019 -