Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Metal enclosure
• Long life
• High level of contact reliability with low voltages and currents
• Adjustable ball latch to 400 N
• 2 cable entries M 20 x 1.5
• Spring-loaded actuators
• 2 switches with different actuating functions in one enclosure
• 84,6 mm x 103,6 mm x 46,5 mm

 
Preferred typ
 
Ordering details
 
Product type descriptionAZ 415-02/02ZPK - Ordering suffix
Article number101164609
EAN Code4030661206509
eCl@ss27-27-26-02
 
Approval
 
Approval


 
Classification
 
StandardsEN ISO 13849-1
B10d Normally-closed contact (NC)2.000.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightAZ 415
StandardsEN 60947-5-1, BG-GS-ET-15
Compliance with the Directives (Y/N) Yes
Number of guard doors1
Materials
- Material of the housingsAluminium
- Material of the contactsSilver
Housing coatingpainted
Weight595
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section2 x 0,75
- Max. Cable section2 x 1.5
Mechanical life> 1.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
higher Latching force (Y/N)Yes
Latching force80 N … 400 N
Positive break force31
positive break travel3.8
Max. Actuating speed0,2 m/s
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+70
Protection classIP67 to IEC/EN 60529
 
Electrical data
 
Design of control elementOpener (NC)
Switching principleCreep circuit element
Number of auxiliary contacts0
Number of safety contacts4
Rated impulse withstand voltage Uimp4 kV
Rated insulation voltage Ui250 V
Thermal test current Ithe6 A
Utilisation categoryAC-15: 230 V / 4 A;
DC-13: 24 V / 4 A
Max. fuse rating6 A gG D-fuse To DIN EN 60269-1
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor84.6
- Height of sensor103.6
- Length of sensor46.5
 
Included in delivery
 
Actuators must be ordered separately.
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Switch travel diagram
 


Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: AZ 415-02/02ZPK-1637
...-1637 0,3 µm gold-plated contacts


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 24.05.2019 - 22:01:59h Kasbase 3.3.0.F.64I