Notes Switch travel diagram Contact closed Contact open Setting range Break point Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel
• Thermoplastic enclosure • Double-insulated • Good resistance to oil and petroleum spirit • 30 mm x 88,5 mm x 30 mm • Actuator heads can be repositioned by 4 x 90° • Cable entry 1 M 20 x 1.5
All indications about the cable section are including the conductor ferrules.
Design of actuating element
Swivel lever
Opening angle
2 x 90 °
Positive break angle
12.5 °
Positive break torque
18.5 Ncm
actuator
78 mm
Ambient conditions
Ambient temperature
- Min. environmental temperature
−30 °C
- Max. environmental temperature
+80 °C
Protection class
IP67
Electrical data
Design of control element
Opener (NC)
Switching principle
Creep circuit element
Number of auxiliary contacts
0
Number of safety contacts
2
Rated impulse withstand voltage Uimp
6 kV
Rated insulation voltage Ui
500 V
Thermal test current Ithe
10 A
Utilisation category
AC-15: 230 V / 4 A, DC-13: 24 V / 1 A
Max. fuse rating
6 A gG D-fuse
notice
Caution! The versions with connector may only be used in PELV circuits to EN 60204-1.
ATEX
Explosion protection categories for gases
None
Explosion protected category for dusts
None
Dimensions
Dimensions of the sensor
- Width of sensor
30
- Height of sensor
161
- Length of sensor
30
Diagram
Note Diagram positive break NC contact active no active Normally-open contact Normally-closed contact
Switch travel diagram
Notes Switch travel diagram Contact closed Contact open Setting range Break point Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel
Ordering suffix
The applicable ordering suffix is added at the end of the part number of the safety switch. Order example: T4C 236-02Z-ST
...-ST
M12 connector with A-coding Rated impulse withstand voltage Uimp: 0,8 kV Rated insulation voltage Ui: 50 V Operating current Ie: AC-15: 50 V / 4 A Caution! The versions with connector may only be used in PELV circuits to EN 60204-1.
...-2310
M12 connector with B-coding Rated impulse withstand voltage Uimp: 0,8 kV Rated insulation voltage Ui: 50 V Operating current Ie: AC-15 50 V / 4 A Caution! The versions with connector may only be used in PELV circuits to EN 60204-1.
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
22.02.2019 -