Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Metal enclosure
• 2 Contacts
• 67 mm x 75 mm x 43 mm ( basic component)
• With large after-travel
• Actuator head with captive stainless steel ball actuator
• 3 Cable entry M 20 x 1.5

 
 
Ordering details
 
Product type descriptionM2S 015-11Y - Ordering suffix
Article number101160497
EAN Code4030661190167
eCl@ss27-27-06-01
 
Approval
 
Approval CCC
EAC
 
Global Properties
 
Permanent light015 Druckbolzen 2 S
StandardsEN 60947-5-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)No
Standard housing (Y/N)No
Materials
- Material of the housingslight alloy die-casting, painted
- Material of the contactsSilver
Housing coatingpainted
Weight310
Slide formSphere
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section1.5
- Max. Cable section2.5
AWG-Number13
Active principlemechanical
Mechanical life10.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
Design of actuating elementPlunger
Actuating force15 N
Bounce duration≤ 2.5
Switchover time≤ 40
Contact opening2 x 1.2
Actuating speed with vertical actuating angle to switch axis
- Min. Actuating speed1
- Max. Actuating speed1
- Actuating angle20
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−30
- Max. environmental temperature+90
Protection classIP65 to IEC/EN 60529
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
- Change-over contact with double break
- galvanically separated contact bridges
Switching principleSnap switch element
Number of shutters1
Number of openers1
Rated insulation voltage Ui500 V
Thermal test current Ithe10 A
Utilisation categoryAC-15: 400 V / 2,5 A
Max. fuse rating20 A gG D-fuse
 
Dimensions
 
Dimensions of the sensor
- Width of sensor67
- Height of sensor130
- Length of sensor43
Slide diameter10
 
notice
 
noticeActuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch.
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Switch travel diagram
 


Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: M2S 015-11Y- C
...- C Magnetic blow-out
Blow-out magnets available to switch high DC currents
Rated operating current/voltage Ie/Ue: 1 A / 220 V; 4 A / 24 V
Utilisation category: DC-13

...- Q Available with bellows to protect against heavy soiling


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 24.04.2019 - 05:59:11h Kasbase 3.3.0.F.64I