Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• To monitor 1 safety edge(s)
• 2 safety contacts, STOP 0
• 1 Signalling output

 
Preferred typ
 
Ordering details
 
Product type descriptionSE-400C
Article number101153920
EAN Code4030661289175
eCl@ss27-27-92-15
 
Approval
 
Approval TÜV
USA/CAN
 
Classification
 
StandardsEN ISO 13849-1
PLup e
Control categoryup 4
PFH value2.47 x 10 - 8 /h
- noticeup to max. 50000 switching cycles/year
Mission time20 Years
 
Global Properties
 
Permanent lightSE-400C
StandardsEN ISO 13856-2, EN ISO 13849-1
Compliance with the Directives (Y/N) Yes
Product utilisation up to category in accordance with EN 9544
Climatic stressEN ISO 13856-2
Mountingsnaps onto standard DIN rail to EN 60715
- ClearanceIP54
- enclosureIP40
- terminalsIP20
Materials
- Material of the housingsPlastic, PE (Black), Crastin (Grey)
Weight184
Start conditionsAutomatic or Start button
Start input (Y/N)Yes
Feedback circuit (Y/N)No
Reset after disconnection of supply voltage (Y/N)Yes
Automatic reset functionYes
Reset with edge detection (Y/N)Yes
Response time32
Time to readinessapprox. 32 ms
 
Mechanical data
 
Connection typeScrew connection
Cable section
- Min. Cable section
- Max. Cable section2 x 1.5
Detachable terminals (Y/N)No
Mechanical life30.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
Resistance to vibration10 … 55 HZ, Amplitude 0,15 mm
Closing durationapprox. 32 ms
Opening durationtyp. 15 ms
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature+5
- Max. environmental temperature+55
Protection class
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp4 kV
- Overvoltage categoryIII To VDE 0110
- Degree of pollution2 To VDE 0110
 
Electromagnetic compatibility (EMC)
 
EMC ratingconforming to EMC Directive
 
Electrical data
 
Rated DC voltage for controls
- Max. rated DC voltage for controls21.6
- Max. rated DC voltage for controls28.8
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz-
- Max. rated AC voltage for controls, 50 Hz-
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz-
- Max. rated AC voltage for controls, 60 Hz-
Power consumption< 4
Type of actuationDC
Rated operating voltage Ue24 VDC +20% / −10%
Operating current Ieapprox. 150 mA
Electronic protection (Y/N)Yes
 
Inputs
 
Monitored inputs
- Short-circuit recognition (Y/N)Yes
- Wire breakage detection (Y/N)Yes
- Earth connection detection (Y/N)Yes
Cable length200
 
Outputs
 
Stop category0
Number of safety contacts2
Number of auxiliary contacts0
Number of signalling outputs1
Switching capacity
- Switching capacity of the safety contacts230 VAC / 2 A;
24 VDC / 2 A
- Switching capacity of the signaling/diagnostic outputs50 mA
Fuse rating
- Protection of the safety contacts4 A gG D-fuse
Utilisation categoryAC-15: 230 V / 2 A;
DC-13: 24 V / 3 A
Number of undelayed semi-conductor outputs with signaling function1
Number of undelayed outputs with signaling function (with contact)0
Number of delayed semi-conductor outputs with signaling function.0
Number of delayed outputs with signalling function (with contact).0
Number of secure undelayed semi-conductor outputs with signaling function0
Number of secure, undelayed outputs with signaling function, with contact.2
Number of secure, delayed semi-conductor outputs with signaling function0
Number of secure, delayed outputs with signaling function (with contact).0
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Number of LED´s2
LED switching conditions display
- The integrated LEDs indicate the following operating states.
- Safety edge function
- Supply voltage UB
 
Miscellaneous data
 
Applications Safety edges
 
Dimensions
 
Dimensions
Width22.5 mm
Height100 mm
Depth121 mm
 
notice
 
The overall machine safety depends on the professional mounting and installation of the safety monitoring module and the signal transmitter, as well as on the correct and professional electrical connection of the components.
If there it any risk whatsoever, the machine may not be restarted.
 
notice - Wiring example
 
Monitoring the safety edges SE 40 / SE 70 with a safety monitoring unit SE-400C up to PL e and Category 4.
The feedback circuit monitors the position of the contactors KA and KB.
A Start-Reset-Taster (S) can optionally be connected to the feedback circuit.
Both re-initialisation and auto-reset must comply with the requirements of EN 1760-2 (diagram A2, A3).
The wiring diagram is shown for the de-energised condition.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 20.06.2019 - 04:56:47h Kasbase 3.3.0.F.64I