Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Single wire entry with Connecting funnel
• Thermoplastic enclosure
• 1 Actuating planes
• Contact pin in actuator bridge
• 1 cable per clamp
• 2 actuating planes
• Protection class IP10
• Inseparable cover and enclosure
• Enclosure with mounting slots
• Self-cleaning through the frictional mouvement of the contact bridges
• fixing screws M4 undetachable, captive

 
 
Ordering details
 
Product type descriptionAZ 19 K
Article number101150802
EAN Code4030661159140
eCl@ss27-27-26-02
 
Approval
 
Approval-
 
Global Properties
 
Permanent lightAZ 19
StandardsEN 81-20, EN 81-50
Compliance with the Directives (Y/N) Yes
suitable for elevators (Y/N)Yes
MountingEnclosure with mounting slots
Materials
- Material of the housingsglass-fibre reinforced ultramid, self-extinguishing
- Material of the coverglass-fibre reinforced ultramid, self-extinguishing
- Material of the contacts-Silver-plated rivets
Weight40
 
Mechanical data
 
Design of electrical connectionCage clamps, WAGO Cage Clamp
Cable section
- Min. Cable section-
- Max. Cable section2.5
Mechanical life> 1.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
Actuating force2 ± 20
Actuating stroke8
higher Latching force (Y/N)No
With ejection force (Y/N)No
Positive break force10
positive break travel-
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−30
- Max. environmental temperature+70
Relative humidity≤ 95, non-condensing
Fully insulated (Y/N)No
Protection classIP10
 
Electrical data
 
Design of control elementOpener (NC)
Switching principleSelf-cleaning pressure contact
Number of auxiliary contacts0
Number of safety contacts1
Rated impulse withstand voltage4
Rated insulation voltage500
Thermal test current4 A
Utilisation categoryAC-15: 230 V / 2 A,
DC-13: 200 V / 2 A
Max. fuse rating2 A gG D-fuse
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions
- Width50
- Height40
- Depth20
 
Included in delivery
 
Actuators must be ordered separately.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 20.02.2019 - 23:24:07h Kasbase 3.3.0.F.64I