Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• slim design
• 1 Cable entry M 20 x 1.5

 
 
Ordering details
 
Product type descriptionT3K 236-02ZH - Ordering suffix
Article number101145088
EAN Code4030661135885
eCl@ss27-27-26-01
 
Classification
 
B10d Normally-closed contact (NC)20.000.000
 
Global Properties
 
Permanent lightT 236 Winkelhebel 3K
Suitable for safety functions (Y/N)Yes
Weight51
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section0,75
- Max. Cable section2.5
noticeAll indications about the cable section are including the conductor ferrules.
Bounce durationin accordance with actuating speed
Switchover timein accordance with actuating speed
Actuating speed with actuating angle 30° to switch axis
- Min. Actuating speed160 mm/min
- Max. Actuating speed1 m/s
 
Electrical data
 
Design of control elementOpener (NC)
Switching principleSlow action with staggered contacts
- positive break NC contact
Number of auxiliary contacts0
Number of safety contacts2
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Switch travel diagram
 


Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: T3K 236-02ZH-ST
...-ST M12 connector with A-coding
Rated impulse withstand voltage Uimp: 0,8 kV
Rated insulation voltage Ui: 50 V
Operating current Ie: AC-15: 50 V / 4 A
Caution! The versions with connector may only be used in PELV circuits to EN 60204-1.

...-2310 M12 connector with B-coding
Rated impulse withstand voltage Uimp: 0,8 kV
Rated insulation voltage Ui: 50 V
Operating current Ie: AC-15 50 V / 4 A
Caution! The versions with connector may only be used in PELV circuits to EN 60204-1.


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 24.04.2019 - 08:31:21h Kasbase 3.3.0.F.64I