Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Solenoid interlock  ->  AZM 170  ->  AZM 170-11ZK 230 VAC
 Add Product to the basket. 
AZM 170-11ZK 230 VAC
• Thermoplastic enclosure
• Double-insulated
• Compact design
• 90 mm x 84 mm x 30 mm
• 1 Cable entry M 20 x 1.5
• Interlock with protection against incorrect locking.
• Long life
• High holding force
• IDC method of termination
• Manual release

 
 
Ordering details
 
Product type descriptionAZM 170-11ZK 230 VAC - Ordering suffix
Article number101141776
EAN Code4030661123301
eCl@ss27-27-26-03
 
Approval
 
Approval BG
USA/CAN
CCC
 
Classification
 
StandardsEN ISO 13849-1
B10d Normally-closed contact (NC)2.000.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightAZM 170
StandardsEN 60947-5-1, BG-GS-ET-19
Compliance with the Directives (Y/N) Yes
Number of actuating directions2
Active principleelectromechanical
Duty cycle EDMagnet 100 %
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Material of the contactsSilver
Housing coatingNone
Weight310
 
Mechanical data
 
Design of electrical connectionIDC method of termination
Cable section
- Min. Cable section1 x 0,75
- Max. Cable section1 x 1.0, flexible
Mechanical life> 1.000.000 operations
Emergency unlocking device (Y/N)No
- bottom
Manual release (Y/N)Yes
Emergency release (Y/N)No
Latching force5
Positive break force8.5
positive break travel11 mm
Clamping force F1000 N
Max. Actuating speed2 m/s
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25 °C
- Max. environmental temperature+60 °C
Protection classIP67 to IEC/EN 60529
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
noticechange-over contact with double break, type Zb or 2 NC contacts, with galvanically separated contact bridges
Switching principleCreep circuit element
Number of auxiliary contacts1
Number of safety contacts1
Power to unlockYes
Power to lockNo
Rated control voltage Us230 VAC
Power consumptionmax. 10 W
Rated impulse withstand voltage Uimp4 kV
Rated insulation voltage Ui250 V
Thermal test current Ithe10 A
Utilisation categoryAC-15: 230 V / 4 A, DC-13: 24 V / 4 A
Max. fuse rating6 A gG D-fuse
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Miscellaneous data
 
Applications sliding safety guard,
removable guard,
hinged safety guard
 
Dimensions
 
Dimensions of the sensor
- Width of sensor90
- Height of sensor84
- Length of sensor30 mm
 
notice
 
This type termination (IDC) method enables simple connetion of flexible conductors without the need for the use of conductor ferrules
Individual coding available on request
Manual release
• For manual release using M5 triangular key, available as accessory
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Switch travel diagram
 


Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: AZM 170-11ZK 230 VAC-1637
...-1637 0,3 µm gold-plated contacts

...ST-2431 connector M12 , Individual solenoid monitoring


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 19.04.2019 - 08:26:52h Kasbase 3.3.0.F.64I