Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Design M12
• Thermoplastic enclosure
• AC 2-wire
• Double-insulated

 
 
Ordering details
 
Product type descriptionIFL 4-120-10
Article number101141523
EAN Code4030661122250
eCl@ss27-27-01-01
 
Approval
 
Approval CCC
 
Global Properties
 
Permanent lightIFL - M 12
StandardsIEC/EN 60947-5-2; DIN VDE 0660-208
Compliance with the Directives (Y/N) Yes
Operating resource protection classProtection class 2
Materials
- Material of the housingsPlastic
- Material of the nutsPlastic
- Material of the washerperbunan®
- Material of the cable mantlePVC
- Material of the active surfacePlastic
Housing coating
Housing construction formcylinder, thread
Weight80
 
Mechanical data
 
Design of electrical connectionCable H03VV-F
Cable length2
Conductor with strain reliefNo
Conductors2 x 0,5
mechanical installation conditionsnot flush
Switch distance Sn4 mm
Reduction factor 1 met (Y/N)No
Protection circuitinductive interference protection
Pressure resistant (Y/N)No
Tightening torque for nutsA/F 17 max. 90 Ncm
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+70
Protection classIP67 to IEC/EN 60529
 
Electrical data
 
Design of control elementNormally open contact (NO)
Number of wire2
Voltage typeAC, alternating current
Supply voltage
- Min. supply voltage15
- Max. supply voltage250
Rated supply frequency45 … 65
Switch frequencyapprox. 10 HZ
Voltage drop Udapprox. 3.5 V (250 V / 200 mA)
Rated impulse withstand voltage Uimp4 kV
Residual current Ir1 mA
Minimum operating current Im8 mA
Operating current Ie200 mA
 
Outputs
 
Design of control outputTwo-wire
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
- yellow LED
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Length of sensor71
- Diameter of sensorM12
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 24.06.2019 - 05:21:49h Kasbase 3.3.0.F.64I