• Monitoring of BNS range magnetic safety sensors
• 2 safety contacts, STOP 0
• 4 Signalling outputs

 
Preferred typ
 
Ordering details
 
Product type descriptionAES 3075
Article number101138576
EAN Code4030661281360
eCl@ss27-37-19-01
 
Approval
 
Approval BG
USA/CAN
EAC
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508
PLup d
Control categoryup 3
PFH value1.0 x 10-7/h
- noticeup to max. 50.000 switching cycles/year and at max. 80% contact load
SILup 2
Mission time20 Years
 
Global Properties
 
Permanent lightAES 3075
StandardsIEC/EN 60204-1, IEC 60947-5-3, IEC 61508, BG-GS-ET-14, BG-GS-ET-20
Compliance with the Directives (Y/N) Yes
Mountingsnaps onto standard DIN rail to EN 60715
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
Weight300
Start input (Y/N)Yes
Feedback circuit (Y/N)Yes
Start-up test (Y/N)No
Reset after disconnection of supply voltage (Y/N)No
Automatic reset function (Y/N)Yes
Reset with edge detection (Y/N)No
Pull-in delay
- ON delay with automatic startadjustable 0,1 / 1.0 s
Drop-out delay< 50
 
Mechanical data
 
Connection typeScrew connection
Cable section
- Max. Cable section4
Tightening torque for the terminals0,4
Detachable terminals (Y/N)No
noticeAll indications about the cable section are including the conductor ferrules.
restistance to shock30 g / 11 ms
Resistance to vibration To EN 60068-2-610…55 HZ, Amplitude 0,35 mm, ± 15 %
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature0
- Max. environmental temperature+55
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+70
Protection class
- Protection class-EnclosureIP40
- Protection class-TerminalsIP20
- Protection class-ClearanceIP54
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp0,5 kV
- Overvoltage categoryIII To VDE 0110
- Degree of pollution2 To VDE 0110
 
Electromagnetic compatibility (EMC)
 
EMC ratingconforming to EMC Directive
 
Electrical data
 
Rated DC voltage for controls
- Max. rated DC voltage for controls20.4
- Max. rated DC voltage for controls27.6 VDC
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz-
- Max. rated AC voltage for controls, 50 Hz-
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz-
- Max. rated AC voltage for controls, 60 Hz-
Power consumption< 8
Type of actuationDC
Switch frequency3
Rated insulation voltage Ui50 V
Rated operating voltage Ue24 VDC ± 15%
Thermal test current Ithe4 A
Operating current Ie0,3 A without external contactors and additional outputs
Electronic protection (Y/N)No
 
Inputs
 
Monitored inputs
- Short-circuit recognition (Y/N)Yes
- Wire breakage detection (Y/N)Yes
- Earth connection detection (Y/N)No
Number of shutters4
Number of openers4
Input resistanceapprox. 2000 Ω at GND
Input signal "1"10 … 30 VDC
Input signal "0"0 … 2 VDC
Cable length1000 m with 0,75 mm² (for Rated voltage)
 
Outputs
 
Stop category0
Number of safety contacts2
Number of auxiliary contacts0
Number of signalling outputs4
Switching capacity
- Switching capacity of the safety contactsmax. 24 VDC 700 mA (short-circuit proof)
- Switching capacity of the signaling/diagnostic outputsmin. Ue −4V / Y1…Y5: max. 250 mA
Fuse rating
- Protection of the safety contacts4 A gG D-fuse
- Fuse rating for the signaling/diagnostic outputsshort-circuit proof
Signalling outputY1: Guard system 1 off
Y2: Guard system 2 off
Y3: Guard system 3 off
Y4: Guard system 4 off
Y5: System in Classification
Number of undelayed semi-conductor outputs with signaling function4
Number of undelayed outputs with signaling function (with contact)0
Number of delayed semi-conductor outputs with signaling function.0
Number of delayed outputs with signalling function (with contact).0
Number of secure undelayed semi-conductor outputs with signaling function0
Number of secure, undelayed outputs with signaling function, with contact.0
Number of secure, delayed semi-conductor outputs with signaling function0
Number of secure, delayed outputs with signaling function (with contact).0
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Number of LED´s1
 
Integral system diagnosis $missingShortName$
 
Integral system diagnosis ISD
- The following faults are registered by the safety monitoring modules and indicated by ISD
- Failure of door contacts to open or close
- Cross-wire or short-circuit monitoring of the switch connections
- Interruption of the switch connections
- Fault on the input circuits or the relay control circuits of the safety monitoring module
 
Miscellaneous data
 
Applications Safety sensor
Guard system
 
Dimensions
 
Dimensions
- Width75 mm
- Height100 mm
- Depth110 mm
 
notice
 
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
 
notice - Wiring example
 
To secure 4 guard doors up to PL d and Category 3
Monitoring 4 guard door(s), each with a magnetic safety sensor of the BNS range
The feedback circuit monitors the positions of the positive-guided NC contacts on the conactors K3 and K4.
Start push button A start push button (NO) can optionally be connected into the feedback circuit. With the guard door closed, the enabling paths are then not closed until the start push button has been operated.
The NC contacts of the external contactors must be wired in series to X1 (+) and X2.
If less than 4 switches are connected, those S21/S22 terminals which are not used for connection of an NC contact must be fitted with a shorting connection. This is based on the applicable jumper inside the safety monitoring unit being set for the NC-NO configuration.
The switch (H6) connected to terminals X3 and X4 switches the enabling outputs Y14 and Y24 on and off with the guard door closed. If no switch is connected, a jumper connection must be mounted between the terminals X3 and X4.
The wiring diagram is shown with guard doors closed and in de-energised condition.
The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 14.02.2019 - 07:49:26h Kasbase 3.3.0.F.64I