Ordering details |
|
Product type description | AZ 17-02ZRI-B6L - Ordering suffix |
Article number | 101136311 |
EAN Code | 4030661280448 |
eCl@ss | 27-27-26-02 |
|
Approval |
|
Approval | BG
USA/CAN |
|
Classification |
|
Standards | EN ISO 13849-1 |
B10d Normally-closed contact (NC) | 2.000.000 |
Mission time | 20 Years |
notice |  |
|
Global Properties |
|
Permanent light | AZ 17ZI |
Standards | EN 60947-5-1, BG-GS-ET-15 |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
- Material of the actuator | Stainless steel |
- Material of the contacts | Silver |
Housing coating | None |
Weight | 120 |
|
Mechanical data |
|
Design of electrical connection | IDC method of termination |
Cable section including conductor ferrules |
- Min. Cable section | 1 x 0,75 |
- Max. Cable section | 2 x 1.0, flexible |
Mechanical life | > 1.000.000 operations |
higher Latching force (Y/N) | Yes |
Latching force | 30 |
Positive break force | 17 N |
positive break travel | 11 mm |
Max. Actuating speed | 2 m/s |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −30 °C |
- Max. environmental temperature | +80 °C |
Protection class | IP67 to IEC/EN 60529 |
|
Electrical data |
|
Design of control element | Opener (NC) |
Switching principle | Creep circuit element |
Number of auxiliary contacts | 0 |
Number of safety contacts | 2 |
Supply voltage |
- Min. supply voltage |
- Max. supply voltage | 230 V |
Rated impulse withstand voltage Uimp | 4 kV |
Rated insulation voltage Ui | 250 V |
Thermal test current Ithe | 10 A |
Utilisation category | AC-15: 230 V / 4 A DC-13: 24 V / 4 A |
Max. fuse rating | 6 A gG D-fuse |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 30 |
- Height of sensor | 85 |
- Length of sensor | 30 |
|
notice |
|
Actuating radius adjustable, minimum 50 mm, using an hexagonal key wrench 2 mm A/F (a and b) |
The axis of the hinge should be 11 mm above the top edge of the safety switch and in the same plane |
The actuator is not available separately. |
This type termination (IDC) method enables simple connetion of flexible conductors without the need for the use of conductor ferrules |
|
Included in delivery |
|
Not available as spare part |
Included in delivery |
• Individually coded actuator |
• tamperproof screws |
• Slot sealing plugs |
|
Diagram |
|

Note Diagram
positive break NC contact
active
no active
Normally-open contact
Normally-closed contact |
|
Switch travel diagram |
|

Notes Switch travel diagram
Contact closed
Contact open
Setting range
Break point
Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel
|
|
Ordering suffix |
|
The applicable ordering suffix is added at the end of the part number of the safety switch. Order example: AZ 17-02ZRI-B6L-2243
|
...-2243 | Cable output: front
|
|
...-2243 -1 | Cable output: rear
|
|
...-1637 | 0,3 µm gold-plated contacts
|
|
...-6m | Cable length 6 Meter
|
|
...-5m | Cable length 5 Meter
|
|
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
20.02.2019 -
16:20:36h Kasbase 3.3.0.F.64I |