Ordering details |
|
Product type description | AES 1165.3-2214-2 |
Article number | 101131635 |
EAN Code | 4030661049663 |
eCl@ss | 27-37-19-01 |
|
Approval |
|
Approval | BG
USA/CAN
EAC |
|
Classification |
|
Standards | EN ISO 13849-1, IEC 61508 |
PL | up d |
Control category | up 3 |
PFH value | 1.0 x 10-7/h |
- notice | up to max. 50.000 switching cycles/year and at max. 80% contact load |
SIL | up 2 |
Mission time | 20 Years |
|
Global Properties |
|
Permanent light | AES 116x |
Standards | IEC/EN 60204-1, IEC 60947-5-3, IEC 61508, BG-GS-ET-14, BG-GS-ET-20 |
Compliance with the Directives (Y/N)  | Yes |
Climatic stress | IEC 60947-5-3, BG-GS-ET-14 |
Mounting | snaps onto standard DIN rail to EN 60715 |
Terminal designations | IEC/EN 60947-1 |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic, ventilated |
- Material of the contacts | Ag-Ni, 10+0,2 µm gold flashed |
Weight | 165 |
Start conditions | Automatic |
Start input (Y/N) | No |
Feedback circuit (Y/N) | No |
Start-up test (Y/N) | No |
Reset after disconnection of supply voltage (Y/N) | Yes |
Automatic reset function (Y/N) | Yes |
Reset with edge detection (Y/N) | No |
Pull-in delay |
- ON delay with automatic start | adjustable 0,1 / 1.0 s |
Drop-out delay |
- Drop-out delay in case of emergency stop | < 50 |
|
Mechanical data |
|
Connection type | Screw connection |
Cable section |
- Min. Cable section | 0,25 |
- Max. Cable section | 2.5 |
Pre-wired cable | rigid or flexible |
Tightening torque for the terminals | 0,6 |
Detachable terminals (Y/N) | No |
Mechanical life | 20.000.000 operations |
Electrical lifetime | 150.000 operations for 230 VAC, 5 A (cos φ = 1) |
restistance to shock | 30 g / 11 ms |
Resistance to vibration To EN 60068-2-6 | 10…55 HZ, Amplitude 0,35 mm, ± 15 % |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | 0 |
- Max. environmental temperature | +55 |
Storage and transport temperature |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +70 |
Protection class |
- Protection class-Enclosure | IP40 |
- Protection class-Terminals | IP20 |
- Protection class-Clearance | IP54 |
Air clearances and creepage distances To IEC/EN 60664-1 |
- Rated impulse withstand voltage Uimp | 4.8 kV |
- Overvoltage category | III To VDE 0110 |
- Degree of pollution | 2 To VDE 0110 |
|
Electromagnetic compatibility (EMC) |
|
EMC rating | 10 V/m |
|
Electrical data |
|
Rated DC voltage for controls |
- Max. rated DC voltage for controls | - |
- Max. rated DC voltage for controls | - |
Rated AC voltage for controls, 50 Hz |
- Min. rated AC voltage for controls, 50 Hz | 20.4 |
- Max. rated AC voltage for controls, 50 Hz | 26.4 |
Rated AC voltage for controls, 60 Hz |
- Min. rated AC voltage for controls, 60 Hz | 20.4 |
- Max. rated AC voltage for controls, 60 Hz | 26.4 |
Contact resistance | max. 100 mΩ |
Power consumption | < 5 |
Type of actuation | DC |
Switch frequency | 1 |
Rated insulation voltage Ui | 250 V |
Rated operating voltage Ue | 24 VAC -15% / +10% |
Thermal test current Ithe | 6 A |
Operating current Ie | 0,2 A |
Electronic protection (Y/N) | No |
|
Inputs |
|
Monitored inputs |
- Short-circuit recognition (Y/N) | Yes |
- Wire breakage detection (Y/N) | Yes |
- Earth connection detection (Y/N) | Yes |
Number of shutters | 1 |
Number of openers | 2 |
Input resistance | approx. 2000 Ω at GND |
Input signal "1" | 10 … 30 VDC |
Input signal "0" | 0 … 2 VDC |
Cable length | 1000 m with 0,75 mm² (for Rated voltage) |
|
Outputs |
|
Stop category | 0 |
Number of safety contacts | 1 |
Number of signalling outputs | 2 |
Switching capacity |
- Switching capacity of the safety contacts | min.10 mA, max. 6 A |
- Switching capacity of the signaling/diagnostic outputs | 2 potential-free contacts |
Fuse rating |
- Protection of the safety contacts | 6 A gG D-fuse |
Fuse rating for the signaling/diagnostic outputs | short-circuit proof, p-type |
Signalling output | Y1: Guard system 1 on Y2: Guard system 2 on |
Utilisation category To EN 60947-5-1 | AC-15: 230 V / 3 A DC-13: 24 V / 2 A |
Number of undelayed semi-conductor outputs with signaling function | 0 |
Number of undelayed outputs with signaling function (with contact) | 2 |
Number of delayed semi-conductor outputs with signaling function. | 0 |
Number of delayed outputs with signalling function (with contact). | 0 |
Number of secure undelayed semi-conductor outputs with signaling function | 0 |
Number of secure, undelayed outputs with signaling function, with contact. | 0 |
Number of secure, delayed semi-conductor outputs with signaling function | 0 |
Number of secure, delayed outputs with signaling function (with contact). | 0 |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
Number of LED´s | 1 |
|
Integral system diagnosis $missingShortName$ |
|
Integral system diagnosis ISD |
- The following faults are registered by the safety monitoring modules and indicated by ISD |
- Failure of door contacts to open or close |
- Cross-wire or short-circuit monitoring of the switch connections |
- Interruption of the switch connections |
- Failure of the safety relay to pull-in or drop-out |
- Fault on the input circuits or the relay control circuits of the safety monitoring module |
|
Miscellaneous data |
|
Applications | Safety sensor
Guard system |
|
Dimensions |
|
Dimensions |
- Width | 22.5 mm |
- Height | 100 mm |
- Depth | 121 mm |
|
notice |
|
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
|
notice - Wiring example |
|
To secure 2 guard doors up to PL d and Category 3 |
Monitoring 2 guard door(s), each with a magnetic safety sensor of the BNS range |
If one or two external relays or contactors are used to switch the load, the system can then only be classified in Category 3 to EN ISO 13849-1, if exclusion of the fault “Failure of the external contactors” can be substantiated and is documented, e.g. by using reliable down-rated contactors. A second contactor leads to an increase in the level of security by redundant switching to switch the load off. |
Expansion of enable delay time: The enable delay time can be increased from 0,1 s to 1 s by changing the position of a jumper link connection under the cover of the unit. |
The wiring diagram is shown with guard doors closed and in de-energised condition. |
The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix. |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
19.02.2019 -
16:31:56h Kasbase 3.3.0.F.64I |