Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Metal enclosure
• Good resistance to oil and petroleum spirit
• Actuator shaft can be turned 360°
• 110 mm x 110 mm x 84 mm
• 3-channel, alternating monitoring
• 2 Cable entry M 20 x 1.5

 
 
Ordering details
 
Product type descriptionT1V10S 500L-22Z
Article number101131112
EAN Code4030661055459
eCl@ss27-27-26-01
 
Approval
 
Approval CCC
 
Classification
 
StandardsEN ISO 13849-1
B10d Normally-closed contact (NC)20.000.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightT.V10S 500
StandardsEN 60947-5-1, BG-GS-ET-15
Materials
- Material of the housingsAluminium
- Material of the contactsSilver
Housing coatingpainted
Weight665
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable entry M 20 x 1.52
Cable section
- Min. Cable section
- Max. Cable section1 x 1.5 mm²
Design of actuating elementOther
Mechanical life3.000.000 operations
Switching frequencymax. 1000 /h
noticeAll indications about the cable section are including the conductor ferrules.
Shaft boreØ 10
Positive break angle14 °
Positive break torque15 Ncm
socket (Y/N)Yes
Universal joint (Y/N)No
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25 °C
- Max. environmental temperature+80 °C
Protection classIP67
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
Switching principleCreep circuit element
Number of auxiliary contacts3
Number of safety contacts1
Rated impulse withstand voltage Uimp4 kV
Rated insulation voltage Ui250 V
Thermal test current Ithe6 A
Utilisation categoryAC-15: 230 V / 4 A,
DC-13: 24 V / 1 A
Max. fuse rating6 A gG D-fuse
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor110 mm
- Height of sensor110 mm
- Length of sensor84 mm
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 19.02.2019 - 08:07:40h Kasbase 3.3.0.F.64I