Notes Switch travel diagram Contact closed Contact open Setting range Break point Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel
• Enclosure with mounting slots • Non-contact principle • Actuation from front • 5 reed contacts • Long life • LED switching conditions display • connector • Thermoplastic enclosure • Reed-contact to clip-in, on-location assembly
The specifications with regard to the switching distances apply to the actuation of the individually mounted devices without ferromagnetic influence. Any change of the distance, positive either negative, is possible due to ferromagnetic interference. When multiple actuating magnets are used, the mutual interference must be observed.
Type of actuation
Magnet
restistance to shock
60 g, on sine wave oscillation
Latching (Y/N)
Yes
Ambient conditions
Ambient temperature
- Min. environmental temperature
−10
- Max. environmental temperature
+75
Protection class
IP30 to IEC/EN 60529
Electrical data
Design of control element
bistable contact
Number of snap-in contacts
1…5
Switching time - Close
2
Switching time - Open
0,07
Dielectric strength
400
Switching voltage
12…60
Switching current
1 A
Switching capacity
30
Outputs
Design of control output
Reed contakts
LED switching conditions display
LED switching conditions display (Y/N)
Yes
ATEX
Explosion protection categories for gases
None
Explosion protected category for dusts
None
Dimensions
Dimensions of the sensor
- Width of sensor
65
- Height of sensor
20
- Length of sensor
140
notice
The opening and closing functions depend on the direction of actuation, the actuating magnets and the polarity of the actuating magnets.
Included in delivery
Actuators must be ordered separately.
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
20.02.2019 -