Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Design M12
• Metal enclosure
• DC 3-wire
• Connector M12
• higher switching distance

 
 
Ordering details
 
Product type descriptionIFL 4B-12-01STPK1
Article number101117695
EAN Code4030661047713
eCl@ss27-27-01-01
 
Approval
 
Approval CCC
 
Global Properties
 
Permanent lightIFL - M 12
StandardsIEC/EN 60947-5-2; DIN VDE 0660-208
Compliance with the Directives (Y/N) Yes
Operating resource protection classNone
Materials
- Material of the housingsBrass
- Material of the nutsBrass, nickel-plated
- Material of the active surfacePlastic
Housing coatingnickel-plated
Housing construction formcylinder, thread
Weight25
 
Mechanical data
 
Design of electrical connectionConnector M12
mechanical installation conditionsQuasi-embeddable
- Steelx ≥ 2.4 mm
- other metalx ≥ 1.2 mm
Switch distance Sn4 mm
Reduction factor 1 met (Y/N)No
Protection circuitinductive interference protection, Protection against polarity reversal, short-circuit and overload proof (pulsed)
Pressure resistant (Y/N)No
Tightening torque for nutsA/F 17 max. 1500 Ncm
- in the shell core area: max. 500 Ncm
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+70
Protection classIP67 to IEC/EN 60529
 
Electrical data
 
Design of control elementOpener (NC)
Number of wire3
Voltage typeDC, direct current
Supply voltage
- Min. supply voltage5
- Max. supply voltage40
Switch frequencyapprox. 550 HZ
Voltage drop Udapprox. 1.3 V (200 mA)
Operating current Ie200 mA
No-load current I0approx. 0,5 mA (24 V)
 
Outputs
 
Design of control outputPNP
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
- yellow LED
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Length of sensor61
- Diameter of sensorM12
 
notice
 
Instead of nuts, a mounting clamp can be provided.
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 23.02.2019 - 22:52:25h Kasbase 3.3.0.F.64I