Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Thermoplastic enclosure
• Concealed mounting possible
• Insensitive to transverse misalignment
• 88 mm x 25 mm x 13 mm
• Long life
• no mechanical wear
• Insensitive to soiling
• AS-Interface Safety at Work available

 
Preferred typ
 
Ordering details
 
Product type descriptionBNS 33-11Z
Article number101107770
EAN Code4030661024301
eCl@ss27-27-24-02
 
Approval
 
Approval BG
USA/CAN
EAC
 
Classification
 
StandardsEN ISO 13849-1
B10d Normally-closed contact/Normally open contact (NC/NO)25.000.000
- noticeat max. 20% contact load
Mission time20 Years
notice
 
Global Properties
 
Permanent lightBNS 33
StandardsIEC 60947-5-3, BG-GS-ET-14
Compliance with the Directives (Y/N) Yes
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
- Material of the cable mantlePVC
Weight62
Monitoring function of downstream devices (Y/N)No
Prerequisite evaluation unitYes
Recommended safety-monitoring module
Recommended actuatorBPS 33, BPS 33-2326
 
Mechanical data
 
Design of electrical connectionCable
Cable length1
Conductors0,25
AWG-Number23
mechanical installation conditionsnot flush
Active areaSide
Ensured switch distance ON Sao5 mm / 8 mm
- BPS 33-2326 = 8 mm Actuating magnet
- BPS 33 = 5 mm Actuating magnet
Ensured switch distance OFF Sar15 mm / 18 mm
- BPS 33-2326 = 18 mm Actuating magnet
- BPS 33 = 15 mm Actuating magnet
Repeat accuracy R R≤ 0,1 x Sao
Type of actuationMagnet
Direction of motionhead-on with regard to the active surface
restistance to shock30 g / 11 ms
Resistance to vibration10 … 55 HZ, Amplitude 1 mm
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25 °C
- Max. environmental temperature+70 °C
Storage and transport temperature
- Min. Storage and transport temperature−25 °C
- Max. Storage and transport temperature+70 °C
Protection classIP67
 
Electrical data
 
Integrated Safety monitoring module available (Y/N)No
Cross circuit/short circuit recognition possible (Y/N)Yes
Voltage typeVAC/DC
Switch frequencymax. 5 HZ
Switching voltagemax. 100 VAC/DC
Switching currentmax. 400 mA
Switching capacitymax. 10 W
 
Outputs
 
Design of control outputOther, Reed contakts
Number of shutters1
Number of openers1
 
Electrical data - Safety outputs
 
Number of secure semi-conductor outputs0
Number of secure outputs with contact0
 
Electrical data - Diagnostic output
 
Number of semi-conductor outputs with signaling function0
Number of outputs with signaling function that already have a contact0
 
LED switching conditions display
 
LED switching conditions display (Y/N)No
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor88 mm
- Height of sensor25 mm
- Length of sensor13 mm
 
notice
 
Contact symbols shown for the closed condition of the guard device.
The contact configuration for versions with or without LED is identical.
 
Included in delivery
 
Actuators must be ordered separately.
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal