Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Design 385
• Thermoplastic enclosure
• DC 4-wire
• Double-insulated
• 3 cable entries M 20 x 1.5

 
 
Ordering details
 
Product type descriptionIFL 50-385-11ZNG - Ordering suffix
Article number101096653
EAN Code4030661041131
eCl@ss27-27-01-01
 
Approval
 
Approval CCC
 
Global Properties
 
Permanent lightIFL - 385
StandardsIEC/EN 60947-5-2; DIN VDE 0660-208
Compliance with the Directives (Y/N) Yes
Operating resource protection classProtection class 2
Materials
- Material of the housingsPlastic
Housing coatingNone
Housing construction formBlock
Weight410
 
Mechanical data
 
Design of electrical connectionScrew connection
Conductor with strain reliefNo
Cable section
- Min. Cable section
- Max. Cable section2 x 1.5
mechanical installation conditionsnot flush
Switch distance Sn50 mm
Switch distance 70 mm available on request
Reduction factor 1 met (Y/N)No
Protection circuitinductive interference protection, Protection against polarity reversal
Pressure resistant (Y/N)No
• Wiring compartment
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+70
Protection classIP67 to IEC/EN 60529
 
Electrical data
 
Design of control elementNormally open contact (NO) and Opener (NC) (antivalent)
Number of wire4
Voltage typeDC, direct current
Supply voltage UB
- Min. supply voltage10
- Max. supply voltage60
Switch frequencyapprox. 25 HZ
Voltage drop Udapprox. 1.5 V (400 mA)
Operating current Ie400 mA
No-load current I0approx. 5.5 mA (24 V)
 
Outputs
 
Design of control outputNPN
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
- yellow LED
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor80
- Height of sensor135
- Length of sensor40
 
notice
 
Mounting angle HW 385-1 to simplify mounting available
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: IFL 50-385-11ZNG-1665-1
...-1665-1 Short-circuit- and overload-proof
Operating current Ie = 0,003 mA
Voltage drop U
d approx. 7.5 V


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 17.06.2019 - 03:54:52h Kasbase 3.3.0.F.64I