Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Design M 18 x 1
• Metal enclosure
• AC 2-wire
• Double-insulated
• Connector M18

 
 
Ordering details
 
Product type descriptionIFL 10-180-01ST
Article number101092428
EAN Code4030661024219
eCl@ss27-27-01-01
 
Approval
 
Approval CCC
 
Global Properties
 
Permanent lightIFL - M18
StandardsIEC/EN 60947-5-2; DIN VDE 0660-208
Compliance with the Directives (Y/N) Yes
Operating resource protection classProtection class 2
Materials
- Material of the housingsPlastic
- Material of the nutsPlastic
- Material of the washerperbunan®
- Material of the active surfacePlastic
Housing coatingNone
Housing construction formcylinder, thread
Weight28
 
Mechanical data
 
Design of electrical connectionConnector M18
Conductor with strain reliefNo
mechanical installation conditionsnot flush
Switch distance Sn10 mm
Reduction factor 1 met (Y/N)No
Protection circuitinductive interference protection
Pressure resistant (Y/N)No
Tightening torque for nutsA/F 24 max. 300 Ncm
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+70
Protection classIP67 to IEC/EN 60529
 
Electrical data
 
Design of control elementOpener (NC)
Number of wire2
Voltage typeAC, alternating current
Supply voltage UB
- Min. supply voltage15
- Max. supply voltage250
Rated supply frequency45 … 65
Switch frequencyapprox. 10 HZ
Voltage drop Udapprox. 4.5 V (250 V / 200 mA)
Rated impulse withstand voltage Uimp4 kV
Residual current Ir1 mA
Minimum operating current Im10 mA
Operating current Ie500 mA
 
Outputs
 
Design of control outputTwo-wire
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
- yellow LED
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Length of sensor91
- Diameter of sensorM18
 
notice
 
Instead of nuts, a mounting clamp can be provided.
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 19.04.2019 - 03:15:54h Kasbase 3.3.0.F.64I