Ordering details |
|
Product type description | T3Z 068-33YR |
Article number | 101087885 |
EAN Code | 4030661057262 |
eCl@ss | 27-37-12-90 |
|
Approval |
|
Approval | CCC |
|
Classification |
|
Standards | EN ISO 13849-1 |
B10d Normally-closed contact (NC) | 100.000 |
Mission time | 20 Years |
notice |  |
|
Global Properties |
|
Permanent light | T3Z 068 |
Standards | IEC 60947-5-1, IEC 60947-5-5, ISO 13850 |
Materials |
- Material of the housings | cast iron, painted |
- Material of the cover | cast iron, painted |
- Material of the contacts | Silver |
Weight | 4635 |
Emergency-Stop button (Y/N) | No |
|
Mechanical data |
|
Design of electrical connection | Screw connection |
Cable section |
- Min. Cable section | 0,75 |
- Max. Cable section | 1.5 |
Mechanical life | 50000 operations |
notice | All indications about the cable section are including the conductor ferrules. |
Actuating force | max. 50 N (30 N in direction of rope) |
Indicator lamp (Y/N) | No |
Key reset (Y/N) | No |
Pull-ring reset (Y/N) | Yes |
Positive break angle | 32 ° |
Positive break torque | 18 Ncm |
Positive break force | 50 N |
Length of wire | max. 2 x 50 m |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −30 °C |
- Max. environmental temperature | +90 °C |
Protection class | IP65 to IEC/EN 60529 |
|
Electrical data |
|
Design of control element | Normally open contact (NO), Opener (NC) |
Switching principle | Creep circuit element |
Number of auxiliary contacts | 3 |
Number of safety contacts | 3 |
Rated impulse withstand voltage Uimp | 4 kV |
Rated insulation voltage Ui | 250 V |
Thermal test current Ithe | 10 A |
Utilisation category | AC-15: 230 V / 2,5 A, DC-13: 24 V / 6 A |
Max. fuse rating | 6 A gG D-fuse |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
notice |
|
At 3 m distance intermediate wire supports are required, see accessories |
|
Switch travel diagram |
|

Notes Switch travel diagram
Contact closed
Contact open
Setting range
Break point
Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel
|
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am