Notes Switch travel diagram Contact closed Contact open Setting range Break point Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel
• Metal enclosure • 4 or 6 Contacts • 194 mm x 123 mm x 130 mm (basic component) • 3 cable entries M 25 x 1.5 • Continuous adjustment of lever position 360°
All indications about the cable section are including the conductor ferrules.
Design of actuating element
Roller lever
Contact opening
2 x 4
Actuation direction
each time 60° right-hand side and left-hand side rotation
Actuating speed with vertical actuating angle to switch axis
- Min. Actuating speed
0,05
- Max. Actuating speed
3
- Actuating angle from left of switch axis
30
- Actuating angle from right of switch axis
30
Ambient conditions
Ambient temperature
- Min. environmental temperature
−30
- Max. environmental temperature
+90
Protection class
IP65 to IEC/EN 60529
Electrical data
Design of control element
Normally open contact (NO)
- Change-over contact with double break
- galvanically separated contact bridges
Switching principle
Snap switch element
Number of shutters
2 left / 2 right
Number of openers
0
Rated impulse withstand voltage
6
Rated insulation voltage
500
Thermal test current
25 A
Utilisation category
AC-15: 230 V / 10 A
Max. fuse rating
25 A gG D-fuse
Dimensions
Dimensions of the sensor
- Width of sensor
194
- Height of sensor
225
- Length of sensor
175
Roller wide
12
Roller diameter
36
Ordering suffix
The applicable ordering suffix is added at the end of the part number of the safety switch. Order example: MV 471-20/20Y- 1
...- 1
...-RMS
Available with metal roller
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
16.02.2019 -
12:19:27h Kasbase 3.3.0.F.64I