• Design Ø 40 mm
• 1 Cable entry M 16 x 1.5
• Thermoplastic enclosure
• DC 4-wire
• Double-insulated

 
Preferred typ
 
Ordering details
 
Product type descriptionIFL 20-400-11P - Ordering suffix
Article number101059986
EAN Code4030661038421
eCl@ss27-27-01-01
 
Approval
 
Approval CCC
 
Global Properties
 
Permanent lightIFL - Ø 40 mm
StandardsIEC/EN 60947-5-2; DIN VDE 0660-208
Compliance with the Directives (Y/N) Yes
Operating resource protection classProtection class 2
Materials
- Material of the housingsPlastic
- Material of the active surfacePlastic
- Material of the terminal fixingPlastic
Housing coatingNone
Housing construction formcylinder smooth
Weight175
 
Mechanical data
 
Design of electrical connectionScrew connection
Conductor with strain reliefNo
Cable section
- Min. Cable section
- Max. Cable section1 x 1.5
mechanical installation conditionsnot flush
Switch distance Sn20 mm
Reduction factor 1 met (Y/N)No
Protection circuitinductive interference protection, Protection against polarity reversal
Pressure resistant (Y/N)No
• Wiring compartment
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+70
Protection type IPIP65
 
Electrical data
 
Design of control elementNormally open contact (NO) and Opener (NC) (antivalent)
Number of wire4
Voltage typeDC, direct current
Supply voltage UB
- Min. supply voltage10
- Max. supply voltage60
Switch frequencyapprox. 100 HZ
Voltage drop Udapprox. 1.5 V (400 mA)
Operating current Ie400 mA
No-load current I0approx. 5.5 mA (24 V)
 
Outputs
 
Design of control outputPNP
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
- yellow LED
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor40
- Height of sensor40
- Length of sensor108
- Diameter of sensor40 mm
 
notice
 
Clamp H 40 is included in delivery
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: IFL 20-400-11P-1665-1
...-1665-1 short-circuit and overload proof
Operating current Ie: 300 mA
Voltage drop Ud: approx. 1 V (300 mA)


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal