Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Metal enclosure
• 118 mm x 155 mm x 64 mm ( basic component)
• With latching end position
• Actuator heads can be repositioned by 4 x 90°
• Change in actuating direction by repositioning actuator head
• Case-hardened lever
• 2 cable entries M 20 x 1.5

 
 
Ordering details
 
Product type descriptionT2C 461-31Y - Ordering suffix
Article number101059727
EAN Code
eCl@ss27-27-06-01
 
Approval
 
Approval
 
Global Properties
 
Permanent light461 Gabelhebel 2C
StandardsEN 60947-5-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)No
Standard housing (Y/N)No
Materials
- Material of the housingscast iron, galvanized
- Material of the contactsSilver
Housing coatingpainted
Weight2300
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section1.5
- Max. Cable section2.5
AWG-Number13
Active principlemechanical
Mechanical life10.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
Design of actuating elementFork lever
Bounce duration
Switchover time
Contact opening2 x 6
Actuating speed with vertical actuating angle to switch axis
- Min. Actuating speed1
- Max. Actuating speed0,5
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−30
- Max. environmental temperature+90
Protection classIP65 to IEC/EN 60529
 
Electrical data
 
Design of control elementNormally open contact (NO) Opener (NC)
- with double break
Switching principleCreep circuit element
- positive break NC contact
Number of shutters3
Number of openers1
Rated impulse withstand voltage6
Rated insulation voltage400
Thermal test current16 A
Utilisation categoryAC-15: 400 V / 4 A
Max. fuse rating16 A gG D-fuse
 
Dimensions
 
Dimensions of the sensor
- Width of sensor118
- Height of sensor250
- Length of sensor64
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: T2C 461-31Y- 1276-2
...- 1276-2 gold-plated contacts

...- H Slow action with staggered contacts

...- UE Slow action with overlapping contacts


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 23.07.2019 - 02:44:14h Kasbase 3.3.0.F.64I