Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• 2 cable entries M 25 x 1.5
Data  

 
 
Ordering details
 
Product type descriptionT2S 452-12Y - Ordering suffix
Article number101058585
EAN Code
eCl@ss27-27-06-01
 
Global Properties
 
Permanent light452 Teleskopdruckbolzen 2S
Suitable for safety functions (Y/N)No
Weight1727
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section1.5
- Max. Cable section2.5
AWG-Number13
Mechanical life10.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
Bounce duration
Switchover time
Contact opening2 x 6
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
- with double break
Switching principleCreep circuit element
- positive break NC contact
Number of shutters1
Number of openers2
Rated impulse withstand voltage6
Rated insulation voltage400
Utilisation categoryAC-15: 400 V / 4 A
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: T2S 452-12Y- H
...- H Slow action with staggered contacts

...- UE Slow action with overlapping contacts


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 16.02.2019 - 18:54:40h Kasbase 3.3.0.F.64I