Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Metal enclosure
• 118 mm x 127 mm x 64 mm ( basic component)
• With large after-travel
• Actuator head with captive stainless steel ball actuator
• 2 cable entries M 25 x 1.5

 
 
Ordering details
 
Product type descriptionT2S 452-02Y - Ordering suffix
Article number101058578
EAN Code
eCl@ss27-27-06-01
 
Approval
 
Approval
 
Global Properties
 
Permanent light452 Teleskopdruckbolzen 2S
StandardsEN 60947-5-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)No
Standard housing (Y/N)No
Materials
- Material of the housingscast iron, galvanized
- Material of the contactsSilver
Housing coatingpainted
Weight1900
Slide formSphere
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section1.5
- Max. Cable section2.5
AWG-Number13
Active principlemechanical
Mechanical life10.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
Design of actuating elementPlunger
Bounce duration
Switchover time
Contact opening2 x 6
Actuating speed with vertical actuating angle to switch axis
- Min. Actuating speed1
- Max. Actuating speed1
- Actuating angle20
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−30
- Max. environmental temperature+90
Protection classIP65 to IEC/EN 60529
 
Electrical data
 
Design of control elementOpener (NC)
- with double break
Switching principleCreep circuit element
- positive break NC contact
Number of shutters0
Number of openers2
Rated impulse withstand voltage6
Rated insulation voltage400
Thermal test current16 A
Utilisation categoryAC-15: 400 V / 4 A
Max. fuse rating16 A gG D-fuse
 
Dimensions
 
Dimensions of the sensor
- Width of sensor118
- Height of sensor189
- Length of sensor64
Slide diameter10
 
notice
 
noticeActuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch.
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: T2S 452-02Y- 1276-2
...- 1276-2 gold-plated contacts

...- H Slow action with staggered contacts

...- Q Available with bellows to protect against heavy soiling


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 23.07.2019 - 02:37:40h Kasbase 3.3.0.F.64I