Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Metal enclosure
• 2 Contacts
• 106 mm x 181 mm x 63 mm
• Suitable for heavy duty
• 2 cable entries

 
 
Ordering details
 
Product type descriptionT. 441-11Y-14 - Ordering suffix
Article number101056537
EAN Code4030661019949
eCl@ss27-27-06-01
 
Approval
 
Approval CCC
 
Global Properties
 
Permanent light441 Schlaffseilschalter
StandardsEN 60947-5-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)No
Standard housing (Y/N)No
Materials
- Material of the housingscast iron, galvanized
- Material of the contactsSilver
Housing coatingpainted
Weight1855
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section1.5
- Max. Cable section2.5
AWG-Number13
Active principlemechanical
Mechanical life10.000.000 operations
Switching frequencymax. 3000 /h
noticeAll indications about the cable section are including the conductor ferrules.
Contact opening2 x 6
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−30
- Max. environmental temperature+90
Protection classIP65 to IEC/EN 60529
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
- with double break
Switching principleCreep circuit element
Number of shutters1
Number of openers1
Rated impulse withstand voltage Uimp6 kV
Rated insulation voltage Ui400 V
Thermal test current Ithe16 A
Utilisation categoryAC-15: 400 V / 4 A
Max. fuse rating16 A gG D-fuse
 
Dimensions
 
Dimensions of the sensor
- Width of sensor106
- Height of sensor181
- Length of sensor63
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Switch travel diagram
 


Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: T. 441-11Y-14-T
...-T Temperature-resistant and tropical version with ceramic insulation for -40°C … +200°C
Rated insulation voltage Ui: 500 V (Snap action)

...-K Tropical version with ceramic insulation
Rated insulation voltage Ui: 500 V (Snap action)

...- 1276-2 gold-plated contacts

...- UE Slow action with overlapping contacts


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 22.02.2019 - 02:36:30h Kasbase 3.3.0.F.64I