Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Metal enclosure
• 4 Contacts
• 67 mm x 130 mm x 43 mm ( basic component)
• Actuator heads can be repositioned by 4 x 90°
• Free movement of actuator from other side
• 3 Cable entry M 20 x 1.5

 
 
Ordering details
 
Product type descriptionT2K 017-31Y - Ordering suffix
Article number101054964
EAN Code
eCl@ss27-27-06-01
 
Approval
 
Approval CCC
EAC
 
Global Properties
 
Permanent light017 Kipphebel 2K
StandardsEN 60947-5-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)No
Standard housing (Y/N)No
Materials
- Material of the housingslight alloy die-casting, painted
- Roller materialPlastic
- Material of the contactsSilver
Housing coatingpainted
Weight455
Slide formCastor
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section1.5
- Max. Cable section2.5
AWG-Number13
Active principlemechanical
Mechanical life5.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
Design of actuating elementRocking offset roller lever
Actuating force8.5 N
Bounce duration
Switchover time
Contact opening2 x 2.5
Actuating speed with vertical actuating angle to switch axis
- Min. Actuating speed1
- Max. Actuating speed0,5
- Actuating angle from left of switch axis45
- Actuating angle from right of switch axis60
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−30
- Max. environmental temperature+90
Protection classIP65 to IEC/EN 60529
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
- Change-over contact with double break
Switching principleCreep circuit element
- positive break NC contact
Number of shutters3
Number of openers1
Rated insulation voltage Ui500 V
Thermal test current Ithe10 A
Utilisation categoryAC-15: 400 V / 4 A
Max. fuse rating20 A gG D-fuse
 
Dimensions
 
Dimensions of the sensor
- Width of sensor67
- Height of sensor185
- Length of sensor43
Roller wide8.5
Roller diameter20
 
notice
 
noticeActuation only possible from one side
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: T2K 017-31Y- C
...- C Magnetic blow-out
Blow-out magnets available to switch high DC currents
Rated operating current/voltage Ie/Ue: 1 A / 220 V; 4 A / 24 V
Utilisation category: DC-13

...- UE Slow action with overlapping contacts

...- H Slow action with staggered contacts

...-RMS Available with metal roller