Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Fail-safe standstill monitors
• Sensor-free detection of standstill by monitoring e.m.f.
• Direct connection to three-phase motors
• Suitable for connection to a frequency converter with the following interface date: rotary hysteresis 0 ... 1000 Hz; switching frequency of the end level up to 16 kHz; engine voltage range 0 ... 400 V
• This fail-safe standstill monitor has the particular advantage that no adjustment for a required-value is needed during comissioning.
• 3 safety contacts, STOP 0
• 1 Signalling output

 
 
Ordering details
 
Product type descriptionAZR31S1/24VDC
Article number101049677
EAN Code4250116202546
eCl@ss27-37-19-01
 
Approval
 
Approval BG
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508, EN 60947-5-1
PLup e (STOP 0)
Control categoryup 4 (STOP 0)
DC99% (STOP 0)
CCF> 65 points
PFH value≤ 2,0.0 x 10-8/h
SILup 3 (STOP 0)
Mission time20 Years
- noticeThe PFH value is applicable for the combinations listed in the table for contact load (K) (current through enabling paths) and switching cycle number (n-op/y).
In case of 365 operating days per year and a 24-hour operation, this results in the specified switching cycle times (t-cycle) for the relay contacts.
Diverging applications on request.
 
Global Properties
 
Permanent lightAZR31S1
StandardsIEC/EN 60204-1, EN 60947-5-1, EN ISO 13849-1, IEC 61508
Compliance with the Directives (Y/N) Yes
Climatic stressEN 60068-2-78
Mountingsnaps onto standard DIN rail to EN 60715
Terminal designationsIEC/EN 60947-1
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
- Material of the contactsAgSn0, self-cleaning, positive action
Weight480
Start conditionsAutomatic
Start input (Y/N)No
Feedback circuit (Y/N)Yes
Start-up test (Y/N)No
Automatic reset function (Y/N)Yes
Reset with edge detection (Y/N)No
Pull-in delay
- ON delay with automatic startapprox. 7 seconds after detection of the standstill
Drop-out delay
- Drop-out delay in case of power failure
- Drop-out delay in case of emergency stop< 15
 
Mechanical data
 
Connection typeScrew connection
Cable section
- Min. Cable section0,25
- Max. Cable section2.5
Pre-wired cablerigid or flexible
Tightening torque for the terminals0,6
Detachable terminals (Y/N)No
Mechanical life10.000.000 operations
Electrical lifetimeDerating curve available on request
restistance to shock30 G / 11 ms
Resistance to vibration To EN 60068-2-610…55 HZ, Amplitude 0,35 mm
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+45
Storage and transport temperature
- Min. Storage and transport temperature−40
- Max. Storage and transport temperature+85
Protection class
- Protection class-EnclosureIP40
- Protection class-TerminalsIP20
- Protection class-ClearanceIP54
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp4 kV
- Overvoltage category
- Degree of pollution2 To IEC/EN 60664-1
 
Electromagnetic compatibility (EMC)
 
EMC ratingconforming to EMC Directive
 
Electrical data
 
Rated DC voltage for controls
- Max. rated DC voltage for controls20.4
- Max. rated DC voltage for controls28.8
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz-
- Max. rated AC voltage for controls, 50 Hz-
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz-
- Max. rated AC voltage for controls, 60 Hz-
Contact resistancemax. 100 mΩ
Power consumptionmax. 3.2 W
Type of actuationDC
Rated operating voltage Ue24 VDC −15% / +20%, residual ripple max. 10%
Operating current Ie
Electronic protection (Y/N)No
Fuse rating for the operating voltage0,315 A slow blow
 
Inputs
 
Monitored inputs
- Short-circuit recognition (Y/N)Yes
- Wire breakage detection (Y/N)Yes
- Earth connection detection (Y/N)Yes
Number of shutters0
Number of openers0
Cable length< 10
Conduction resistancemax. 40 Ω
 
Outputs
 
Stop category0
Number of safety contacts3 (13-14, 23-24, 33- 34)
Number of auxiliary contacts1 (41-42)
Number of signalling outputs
Switching capacity
- Switching capacity of the safety contactsmax. 250 V, 6 A ohmic (inductive in case of appropriate protective wiring)
- Switching capacity of the auxiliary contacts41-42: 24 VDC / 2 A
Fuse rating
- Protection of the safety contacts6.3 A slow blow
- Fuse rating for the auxiliary contacts2 A slow blow
Utilisation category To EN 60947-5-1AC-15: 230 V / 6 A
DC-13: 24 V / 6 A
Number of undelayed semi-conductor outputs with signaling function0
Number of undelayed outputs with signaling function (with contact)1
Number of delayed semi-conductor outputs with signaling function.0
Number of delayed outputs with signalling function (with contact).0
Number of secure undelayed semi-conductor outputs with signaling function0
Number of secure, undelayed outputs with signaling function, with contact.3
Number of secure, delayed semi-conductor outputs with signaling function0
Number of secure, delayed outputs with signaling function (with contact).0
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
Number of LED´s5
LED switching conditions display
- The integrated LEDs indicate the following operating states.
- OUT, green: Authorized operation
- ON, green: Supply voltage UB
- A, red: Input signal channel A
- B, red: Input signal channel B
- ERR, red: Error channel A + B
 
Miscellaneous data
 
Applications safe standstill monitoring
 
Dimensions
 
Dimensions
- Width45 mm
- Height73.2 mm
- Depth121 mm
 
notice
 
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
 
notice - Wiring example
 
The sensor-free standstill monitor checks the e.m.f. of the three phase motor.
To secure a guard door
The SRB range guard door monitor checks the position of the guard door.
Monitoring the guard door using a solenoid interlock and a safety switch with separate actuator (A and B).
Release takes place by means of the NO contact (E) only when the run-down movement has been terminated.
After release has taken place, the guard door must be opened.
The wiring diagram is shown with guard doors closed and in de-energised condition.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.