AZM190-11/10RKN-24VDC
• Thermoplastic enclosure
• Long life
• Interlock with protection against incorrect locking.
• 89 mm x 178 mm x 41 mm
• Actuating head can be repositioned by 4 x 90°
• 2 cable entries M 20 x 1.5
• Wiring compartment
• Slim design, particularly suitable for fitting on hinged doors, aluminium profiles and fencing
• Sealing mechanism to prevent the ingress of dirt
• Cut clamp termination
• Emergency release

 
 
Ordering details
 
Product type descriptionAZM190-11/10RKN-24VDC
Article number101030176
EAN Code4030661446332
Replaced article number 101155785
eCl@ss27-27-26-03
 
Approval
 
Approval BG
USA/CAN
CCC
 
Classification
 
StandardsEN ISO 13849-1
B10d Normally-closed contact (NC)2.000.000
B10d Normally open contact (NO)1.000.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightAZM190
StandardsEN 60947-5-1, BG-GS-ET-19
Compliance with the Directives (Y/N) Yes
Number of actuating directions4
Active principleelectromechanical
Duty cycle EDMagnet 100 %
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
- Material of the contactsSilver
Housing coatingNone
Weight480
 
Mechanical data
 
Connection typeScrew connection
Cable section
- Min. Cable section1 x 0,5 mm²
- Max. Cable section1 x 1.5 mm²
Mechanical life2.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
Emergency unlocking device (Y/N)No
- front
Manual release (Y/N)No
Emergency release (Y/N)Yes
Latching force20 N
Positive break force20 N
positive break travel2 x 3.5 mm
Clamping force F1950 N
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature0 °C
- Max. environmental temperature+50 °C
Protection classIP67 to IEC/EN 60529
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
Switching principleCreep circuit element
Number of auxiliary contacts2
Number of safety contacts1
Power to unlockYes
Power to lockNo
Rated control voltage Us24 VDC
Power consumptionmax. 8.5 W
Power consumptionmax. 8.5 W
Rated impulse withstand voltage Uimp4 kV
Rated insulation voltage Ui250 V
Thermal test current Ithe4 A
Utilisation categoryAC-15: 230 V / 4 A,
DC-13: 24 V / 4 A
Max. fuse rating4 A gG D-fuse to DIN EN 60269-1
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Miscellaneous data
 
Applications hinged safety guard
 
Dimensions
 
Dimensions of the sensor
- Width of sensor89 mm
- Height of sensor178 mm
- Length of sensor41 mm
 
notice
 
Emergency release
• For cases of danger
• Mounting only outside the guarded area
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Switch travel diagram
 


Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 19.09.2019 - 03:01:43h Kasbase 3.3.0.F.64I