Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Metal enclosure
• 50 mm x 120 mm x 43 mm
• Long life
• Head positioned to the front

 
 
Ordering details
 
Product type descriptionSCG01.103
Article number101020914
EAN Code
eCl@ss27-27-26-02
 
Approval
 
Approval
 
Classification
 
StandardsEN ISO 13849-1
B10d Normally-closed contact (NC)2.000.000
B10d Normally open contact (NO)1.000.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightSCG
StandardsEN 60947-5-1, BG-GS-ET-15, EN 1088
Compliance with the Directives (Y/N) Yes
Materials
- Material of the housingsAluminium
- Material of the contactsSilver
Housing coatingpainted
Weight325
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section0,5
- Max. Cable section2.5
Mechanical life1.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
higher Latching force (Y/N)No
Positive break force5 N for each NC contact fitted
positive break travel11
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+70
Protection classIP67 to IEC/EN 60529
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
Switching principleCreep circuit element
Number of auxiliary contacts1
Number of safety contacts1
Rated impulse withstand voltage2.5
Rated insulation voltage400
Thermal test current10 A
Utilisation categoryAC-15: 230 V / 8 A
DC-13: 24 V / 5 A
Max. fuse rating10 A gG D-fuse
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor50
- Height of sensor120
- Length of sensor43
 
Included in delivery
 
Actuators must be ordered separately.
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Switch travel diagram
 


Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 22.02.2019 - 09:05:45h Kasbase 3.3.0.F.64I