Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Design M 18 x 1
• Metal enclosure
• DC 3-wire
• miniature body
 
Ordering details
 
Product type description
IFL (1)-(2)(3)-(4)(5)(6)(7)-(8)
 
(1)
5Switch distance 5 mm
8Switch distance 8 mm
10Switch distance 10 mm
 
(2)
18cylinder, thread M18, Metal film
180cylinder, thread M18, Plastic
 
(3)
withoutIncluded in standard version Design
Mminiature body
LLong design
 
(4)
01Opener (NC)
10Normally open contact (NO)
10/01Normally open contact (NO) / Opener (NC) with Wiring compartment
11Normally open contact (NO) / Opener (NC) antivalent
 
(5)
withoutCable
STConnector
TConductor with strain relief
AAlternating current/direct current AC/DC
DDC 2-wire
 
(6)
withoutIncluded in standard version Plug-in connection
2Alternative Plug-in connection
 
(7)
Nn-type
Pp-type
 
(8)
2033Stainless steel enclosure
2130Max. +130°C, without LED switching conditions display