Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
 Add Product to the basket. 
SLC 410-E/R0910-14-BM
NOTICE: Not available! (Replacement: SLC 420)
• Control Category 4

 
 
Ordering details
 
NOTICE: Not available! (Replacement: SLC 420)
Product type descriptionSLC 410-E/R0910-14-BM
Article number101186021
EAN Code4030661343204
eCl@ss27-27-27-04
 
Approval
 
Approval TÜV
USA/CAN
 
Global Properties
 
Permanent lightSLC 410 Sicherheits-Lichtvorhang
StandardsIEC/EN 61496-1/-2
Compliance with the Directives (Y/N) Yes
Operating resource protection classProtection class 3
Safety type in accordance with IEC 61496-14
Materials
- Material of the housingsAluminium
Beam coding (Y/N)Yes
Protection field height910
Range of the protection field0 - 5000
Reaction time22.5
Wave length of the sensors950 nm
Fade-out is possible (Y/N)Yes
Override possible (Y/N)No
reduced resolution (Y/N)No
Clock control possible (Y/N)No
Muting possible (Y/N)No
Restart block (Y/N)No
Master/slave functionmaster
Cascadable (Y/N)Yes
Monitoring function of downstream devices (Y/N)No
Recommended safety-monitoring moduleSCR 402R-301
AZR 311 TL AST LC ST-AS
 
Mechanical data
 
Detection ability for test bodies14
Number of beams90
Design of electrical connectionConnector
- Wiring of the transmitterconnector plug M12, 5-pole
- Wiring of the receiverconnector plug M12, 8-pole
Cable length100
- master / slavemax. 50 m
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature0 °C
- Max. environmental temperature+55 °C
Storage and transport temperature
- Min. Storage and transport temperature−20 °C
- Max. Storage and transport temperature+70 °C
Protection classIP65 to IEC/EN 60529
 
Electrical data
 
Design of output switching element OSSDPNP
Power consumption
- Power consumption Transmitter2
- Power consumption Receiver3
Voltage typeDC
Switching voltage of the OSSD in high state24 V ± 20%
 
Outputs
 
Max. output current at secured output500 mA
 
Electrical data - Safety outputs
 
Number of secure semi-conductor outputs2 piece
Number of secure outputs with contact0 piece
 
Electrical data - Diagnostic output
 
Number of semi-conductor outputs with signaling function0 piece
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
- Status and diagnostics
- 7-segment display
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor45 mm
- Height of sensor1011
- Length of sensor35 mm
 
notice
 
In case of failure (interruption of the 0 V supply) the maximum leakage current is 0,3 mA.
The SLC 410 BM Master can be combined with all slaves of the SLC 410...RFS series.
 
Included in delivery
 
Delivery scope of disposable systemTransmitter + receiver, Mounting angle, T-slot nuts

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 24.08.2019 - 18:59:56h Kasbase 3.3.0.F.64I