Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Thermoplastic enclosure
• Good resistance to oil and petroleum spirit
• Wide range of alternative actuators
• 30 mm x 58,5 mm x 30 mm
• 1 Cable entry M 20 x 1.5
• Double-insulated
• Mounting details to EN 50047
• Actuator heads can be repositioned by 4 x 90°
 
Ordering details
 
Product type description
(1)(2) 2(3)6-(4)Z(5)-(6)-(7)-(8)-(9)
 
(1)
ZSnap action
TSlow action
 
(2)
SPlunger S
RRoller plunger R
4SPlunger 4S
4RRoller plunger 4R
1ROffset roller lever 1R
KOffset roller lever K
3KAngle roller lever 3K
4KAngle roller lever 4K
K4Angle roller lever K4
1HRoller lever 1H
7HRoller lever 7H
10HRod lever 10H
12HRoller lever 12H
14HRoller lever 14H
AFSpring rod lever AF
 
(3)
3slim design
5large design
 
(4)
022 Opener (NC)
111 Normally open contact (NO) / 1 Opener (NC)
202 Normally open contact (NO), (Switch with 2 NO contacts are not for security tasks)
 
(5)
HSlow action with staggered contacts
UESlow action with overlapping contacts
 
(6)
withoutCable entry M20
IDIDC method of termination
NPTcable entry NPT 1/2"
STM12 connector with A-coding
ST-2310M12 connector with B-coding
 
(7)
1297Enclosure with transverse slotted holes
 
(8)
2138Roller lever 7H for Position switches with safety function
 
(9)
1637gold-plated contacts