Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Dansk  Polska  日本語  Türkiye  中文  Português-br  
Home ->
Safety sensors  ->  BNS 16  ->  BNS 16-12ZV
• Thermoplastic enclosure
• Suitable for food processing industry
• Concealed mounting possible
• 52 mm x 90 mm x 32 mm
• Long life
• no mechanical wear
• Insensitive to transverse misalignment
• Insensitive to soiling
• 3 cable entries M 20 x 1.5
• Wiring compartment

Preferred typ
Ordering details
Product type descriptionBNS 16-12ZV
Article number101172553
EAN code4030661301129
Approval BG
StandardsEN ISO 13849-1
B10d Opener/Normally open contact (NC/NO)25.000.000
- noticeat max. 20% contact load
Mission time20 Years
Global Properties
Product nameBNS 16
StandardsIEC 60947-5-3, BG-GS-ET-14
Compliance with the Directives (Y/N) Yes
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
Weight125 g
Coding available (Y/N)Yes
Monitoring function of downstream devices (Y/N)No
Prerequisite evaluation unitYes
Recommended safety-monitoring moduleAES 1135, AES 1136, AES 1165, AES 1166, AES 1165-2250, AES 1185, AES 1235, AES 1236, AES 1265, AES 1266, AES 1337, AES 2135, AES 2136, AES 2335, AES 2336, AES 2535, AES 2536, AES 2365, AES 2366, AES 2565, AES 2566, AES 2285, AES 3075, SRB 202C., SRB 400C.
Recommended actuatorBPS 16
Mechanical data
Design of electrical connectionScrew connection
Cable section
- Min. Cable section0,25 mm²
- Max. Cable section1.5 mm²
mechanical installation conditionsnot flush
Active areafront side
Ensured switch distance ON8 mm
Ensured switch distance OFF18 mm
noticeAll indications about the cable section are including the conductor ferrules.
Type of actuationMagnet
Direction of motionhead-on with regard to the active surface
restistance to shock30 g / 11 ms
Resistance to vibration10 … 55 Hz, Amplitude 1 mm
Ambient conditions
Ambient temperature
- Min. environmental temperature−25 °C
- Max. environmental temperature+70 °C
Storage and transport temperature
- Min. Storage and transport temperature−25 °C
- Max. Storage and transport temperature+70 °C
Protection classIP67
Electrical data
Integrated Safety monitoring module available (Y/N)No
Cross circuit/short circuit recognition possible (Y/N)Yes
Voltage typeVAC/DC
Switch frequencymax. 5 Hz
Switching voltagemax. 100 VAC/DC
Switching currentmax. 400 mA
Switching capacitymax. 10 W
Design of control outputOther, Reed contakts
Number of shutters1 piece
Number of openers2 piece
Electrical data - Safety outputs
Number of secure semi-conductor outputs0 piece
Number of secure outputs with contact0 piece
Electrical data - Diagnostic output
Number of semi-conductor outputs with signaling function0 piece
Number of outputs with signaling function that already have a contact0 piece
LED switching conditions display
LED switching conditions display (Y/N)No
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
Dimensions of the sensor
- Width of sensor52 mm
- Height of sensor90 mm
- Length of sensor39 mm
Contact symbols shown for the closed condition of the guard device.
Included in delivery
Actuators must be ordered separately.

Note Diagram
  positive break NC contact
  no active
  Normally-open contact
  Normally-closed contact

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 26.11.2015 - 00:41:07h Kasbase 3.2.1.F.64I