Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
Home ->
Solenoid interlock  ->  AZM 415  ->  AZM 415-02/20ZPK 24 VAC/DC
 Add Product to the basket. 
AZM 415-02/20ZPK 24 VAC/DC
• Metal enclosure
• Interlock with protection against incorrect locking.
• Robust design
• Long life
• 2 cable entries M 20 x 1.5
• Cut clamp termination
• Adjustable ball latch to 400 N
• 2 switches in one enclosure
• Problem-free opening of stressed doors by means of bell-crank system
• Ex version available
• 130 mm x 100 mm x 46,5 mm

 
 
Ordering details
 
Product type descriptionAZM 415-02/20ZPK 24 VAC/DC - Ordering suffix
Article number101156866
EAN Code4030661179186
eCl@ss27-27-26-03
 
Approval
 
Approval BG
USA/CAN
CCC
 
Classification
 
StandardsEN ISO 13849-1
B10d Normally-closed contact (NC)2.000.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightAZM 415
StandardsEN 60947-5-1, BG-GS-ET-19
Compliance with the Directives (Y/N) Yes
Number of guard doors1
Number of actuating directions1
Active principleelectromechanical
Duty cycle EDMagnet 100 %
Materials
- Material of the housingsAluminium
- Material of the contactsSilver
Housing coatingpainted
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable section
- Min. Cable section2 x 0,75 mm²
- Max. Cable section2 x 2.5 mm²
Mechanical life> 1.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
Emergency unlocking device (Y/N)No
Manual release (Y/N)No
Emergency release (Y/N)No
Latching force150 N … 400 N
Positive break force15 N min.
positive break travel5
Clamping force F3500 N
Max. Actuating speed0,2 m/s
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25 °C
- Max. environmental temperature+50 °C
Protection classIP67 to IEC/EN 60529
 
Electrical data
 
Design of control elementNormally open contact (NO), Opener (NC)
Switching principleCreep circuit element
Number of auxiliary contacts2
Number of safety contacts2
Power to unlockYes
Power to lockNo
Rated control voltage Us24 V AC/DC
Power consumptionmax. 10 W
Rated impulse withstand voltage Uimp4 kV
Rated insulation voltage Ui250 V
Thermal test current Ithe6 A
Utilisation categoryAC-15: 230 V / 4 A,
DC-13: 24 V / 1 A
Max. fuse rating6 A gG D-fuse
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Miscellaneous data
 
Applications sliding safety guard
hinged safety guard
 
Dimensions
 
Dimensions of the sensor
- Width of sensor130
- Height of sensor100
- Length of sensor46.5
 
notice - Dimensional drawing
 
Asetting screw Ball latch
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: AZM 415-02/20ZPK 24 VAC/DC-1637
...-1637 0,3 µm gold-plated contacts


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.