| Ordering details
|
|
|
| Product type description
|
SLC 440-E/R0730-30-01
|
| Article number
|
101216741
|
| EAN code
|
4030661410166
|
|
|
| Approval
|
|
|
| Approval
|
TÜV
USA/CAN
|
|
|
| Classification
|
|
|
| Standards
|
EN ISO 13849-1, EN 62061
|
| PL
|
up e
|
| Control category
|
up 4
|
| PFH value
|
5.14 x 10-9 /h
|
| SIL
|
up 3
|
| Mission time
|
20 Years
|
|
|
| Global Properties
|
|
|
| Product name
|
SLC 440 Sicherheits-Lichtvorhang
|
| Standards
|
EN 61496-1; CLC/TS 61496-2
|
Compliance with the Directives (Y/N)
|
Yes
|
| Operating resource protection class
|
Protection class 3
|
| Safety type in accordance with IEC 61496-1
|
4
|
| Materials
|
| - Material of the housings
|
Aluminium
|
| Weight
|
| Beam coding (Y/N)
|
Yes
|
| Protection field height
|
730 mm
|
| Range of the protection field
|
300 - 10000 mm
|
| Reaction time
|
10 ms
|
| Wave length of the sensors
|
880
|
| Fade-out is possible (Y/N)
|
Yes
|
| Override possible (Y/N)
|
No
|
| reduced resolution (Y/N)
|
No
|
| Clock control possible (Y/N)
|
No
|
| Muting possible (Y/N)
|
No
|
| Restart block (Y/N)
|
Yes
|
| Master/slave function
|
No
|
| Cascadable (Y/N)
|
No
|
| Monitoring function of downstream devices (Y/N)
|
Yes
|
| Recommended safety-monitoring module
|
SRB 301MC
|
|
|
| Mechanical data
|
|
|
| Detection ability for test bodies
|
30 mm
|
| Number of beams
|
36 piece
|
| Design of electrical connection
|
Connector
|
| - Wiring of the transmitter
|
connector plug M12, 4-pole
|
| - Wiring of the receiver
|
connector plug M12, 8-pole
|
| Cable length
|
100 m
|
|
|
| Ambient conditions
|
|
|
| Ambient temperature
|
| - Min. environmental temperature
|
−10 °C
|
| - Max. environmental temperature
|
+50 °C
|
| Storage and transport temperature
|
| - Min. Storage and transport temperature
|
−25 °C
|
| - Max. Storage and transport temperature
|
+70 °C
|
| Protection class
|
IP67 to IEC/EN 60529
|
|
|
| Electrical data
|
|
|
| Design of output switching element OSSD
|
PNP
|
| Power consumption
|
| - Power consumption Transmitter
|
1.8 W
|
| - Power consumption Receiver
|
3.8 W
|
| Voltage type
|
DC
|
| Switching voltage of the OSSD in high state
|
24 V ± 10%
|
| Integrated contactor control (Y/N)
|
Yes
|
|
|
| Outputs
|
|
|
| Max. output current at secured output
|
250 mA
|
|
|
| Electrical data - Safety outputs
|
|
|
| Number of secure semi-conductor outputs
|
2 piece
|
| Number of secure outputs with contact
|
0 piece
|
|
|
| LED switching conditions display
|
|
|
| LED switching conditions display (Y/N)
|
Yes
|
| - Status and diagnostics
|
Yes
|
| - 7-segment display
|
|
|
| ATEX
|
|
|
| Explosion protection categories for gases
|
None
|
| Explosion protected category for dusts
|
None
|
|
|
| Dimensions
|
|
|
| Dimensions of the sensor
|
| - Width of sensor
|
27.8 mm
|
| - Height of sensor
|
811 mm
|
| - Length of sensor
|
33 mm
|
|
|
| notice
|
|
|
| In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA.
|
|
|
| Included in delivery
|
|
|
| Delivery scope of disposable system
|
Transmitter + receiver, Mounting angle
|
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
20.05.2013 -